  6. 3M™ Fire Barrier Pass-Through Device PT4SD, 4 in Square, 6/Case

3M™ Fire Barrier Pass-Through Device PT4SD, 4 in Square, 6/Case

  • 3M Product Number PT4SD
  • 3M ID 7100004181
  • UPC 00051115165979

Cable management solution for electrical, data and communication applications

One-piece, square hinged metal enclosure makes installation fast and easy

Intumescent material and foam smoke seals provide lasting firestop protection

View more details
Frequently viewed resources
PDF (1) Copy 26Tech Data Sheet (PDF, 189KB)

Details

Highlights
  • Cable management solution for electrical, data and communication applications
  • One-piece, square hinged metal enclosure makes installation fast and easy
  • Intumescent material and foam smoke seals provide lasting firestop protection
  • Square shape allows for stacking multiple boxes for ganging
  • Re-enterable for high traffic areas or blank penetrations
  • Firestop tested for up to 3 hours in accordance with ASTM E 814 (UL 1479)

The 3M™ Fire Barrier Pass-Through Device Square are one-piece hinged metal enclosures designed to prevent the passage of fire, smoke and toxic gas. This easily-installed device is ideal for firestopping penetrations in high traffic areas where telecom, data or electrical cables are frequently added or removed. Intumescent material and foam smoke seals achieve up to a 4 hour fire protection rating.

 

3M™ Fire Barrier Pass-Through Device Square
Keep cables organized as well as protected
Simple and Effective for Protecting Critical Equipment
3M™ Fire Barrier Pass-Through Device Square is an ideal firestop solution for through wall penetrations for cabling. This one-piece, square, hinged metal enclosure features a combination of a fixed firestopping intumescent material and foam smoke seals at each end. The re-enterable device installs quickly and easily for new construction or retrofit applications. It is built for square openings and allows for stacking multiple boxes for easy cable management. It is suitable for blank penetrations, or it hinges over existing cables. It can be secured using optional mounting brackets or firestop sealants (sold separately). When adding or removing cables in the penetration, technicians simply remove and reinstall the foam plugs instead of the entire device. This Fire Barrier Pass-Through Device is designed to provide years of dependable through-penetration firestopping with no reapplication or maintenance.
 

 

 

3M™ Fire Barrier Pass-Through Device Square is an ideal firestop solution for through wall penetrations for cabling.
Recommended Applications
  • Vital telecom equipment firestop, especially in high-traffic areas where cable is frequently added or removed
  • Cables — 750 kcmil, Cat 6, fiber optic, 300 pair No. 24 AWG copper telephone cable, thermostat
  • Plastic pipes — ccPVC, PVC, ENT, CPVC, FRPP, PVDF, ccABS, ABS, rigid non-metallic, PEX
  • Metal pipes — copper, steel, iron, flexible gas
  • Insulated — AB/PVC on copper line sets
  • Combinations — metallic, non-metallic and insulated pipes plus cables
  • Blank penetrations
Fully Tested and Approved
Our 3M™ Fire Barrier Pass-Through Device Round are firestop tested to the criteria of ASTM E 814/UL 1479 Standard Test Method for Fire Tests of Penetration Firestop Systems, ASTM E 84/UL 273 Standard Test Method for Surface Burning Characteristics of Building Materials, ASTM E 90 Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements, and ASTM E 413 Classification for Rating Sound Insulation.

Reliable and Affordable Fire Protection
Effective and easy to install, 3M™ Fire Barrier Pass-Through Device Square are part of our family of fire protection products that offer the broadest, long-lasting solutions for a variety of commercial, industrial and residential applications. As a trusted leader in the fire protection industry, 3M offers a broad line of affordable products designed to meet the most demanding firestop requirements. Find the solution you need from the industry-preferred line of fire protection products.
 

 

Typical properties

Resources

Ask a 3M Expert

Close  
For industrial/occupational use only. Not for consumer sale or use.

3M industrial and occupational products are intended, labeled, and packaged for sale to trained industrial and occupational customers for workplace use.  Unless specifically stated otherwise on the applicable product packaging or literature, these products are not intended, labeled, or packaged for sale to or use by consumers (e.g., for home, personal, primary or secondary school, recreational/sporting, or other uses not described in the applicable product packaging or literature), and must be selected and used in compliance with applicable health and safety regulations and standards (e.g., U.S. OSHA, ANSI), as well as all product literature, user instructions, warnings, and other limitations, and the user must take any action required under any recall, field action, or other product use notice.  Misuse of 3M industrial and occupational products may result in injury, sickness, death, or property damage.  For help with product selection and use, consult your on-site safety professional, industrial hygienist, or other subject matter expert.