3M™ Industrial Loadbreak Elbows 5810 Series

  • Ideal for connecting underground cable to transformers, switchgear and junctions that come with loadbreak bushings
  • Cold shrink tube seals from the bottom of the elbow to the cable jacket
  • Specially designed for use on tape shield, wire shield, UniShield® and jacketed concentric neutral types of cables
  • High-quality, peroxide-cured EPDM provides better insulation
 More...
View all details
For industrial/occupational use only. Not for consumer sale or use.
All Options
Showing 24 of 30
Close
Specifications
Attribute Name
Value
Brand
3M™
Cable Type
Compact/Solid, Stranded
Cable Voltage Rating
15 kV, 5 kV, 8 kV
Component Type
Elbow
Conductor Size by Voltage
(15 kV, 100%) 1 AWG, Compact/Solid, (15 kV, 100%) 1 AWG, Stranded, (15 kV, 100%) 1/0 AWG, Compact/Solid, (15 kV, 100%) 1/0 AWG, Stranded, (15 kV, 100%) 1/0-2/0 AWG, Stranded, (15 kV, 100%) 2 AWG, Compact/Solid, (15 kV, 100%) 2 AWG, Stranded, (15 kV, 100%) 2-1 AWG, Stranded, (15 kV, 100%) 2-1/0 AWG, Compact/Solid, (15 kV, 100%) 2/0 AWG, Compact/Solid, (15 kV, 100%) 2/0-3/0 AWG, Compact/Solid, (15 kV, 100%) 250 kcmil, Compact/Solid, (15 kV, 100%) 250 kcmil, Stranded, (15 kV, 100%) 3/0 AWG, Stranded, (15 kV, 100%) 3/0 AWG-250 kcmil, Stranded, (15 kV, 100%) 4 AWG, Stranded, (15 kV, 100%) 4/0 AWG, Compact/Solid, (15 kV, 100%) 4/0 AWG, Stranded, (15 kV, 100%) 4/0 AWG-250 kcmil, Compact/Solid, (15 kV, 133%) 1 AWG, Compact/Solid, (15 kV, 133%) 1 AWG, Stranded, (15 kV, 133%) 1-2/0 AWG, Compact/Solid, (15 kV, 133%) 1/0 AWG, Compact/Solid, (15 kV, 133%) 1/0 AWG, Stranded, (15 kV, 133%) 2 AWG, Compact/Solid, (15 kV, 133%) 2 AWG, Stranded, (15 kV, 133%) 2-1/0 AWG, Stranded, (15 kV, 133%) 2/0 AWG, Compact/Solid, (15 kV, 133%) 2/0 AWG, Stranded, (15 kV, 133%) 2/0-4/0 AWG, Stranded, (15 kV, 133%) 250 kcmil, Compact/Solid, (15 kV, 133%) 250 kcmil, Stranded, (15 kV, 133%) 3/0 AWG, Compact/Solid, (15 kV, 133%) 3/0 AWG, Stranded, (15 kV, 133%) 3/0 AWG-250 kcmil, Compact/Solid, (15 kV, 133%) 4 AWG, Stranded, (15 kV, 133%) 4/0 AWG, Compact/Solid, (15 kV, 133%) 4/0 AWG, Stranded, (5 kV, 100%) 1 AWG, Compact/Solid, (5 kV, 100%) 1 AWG, Stranded, (5 kV, 100%) 1-1/0 AWG, Compact/Solid, (5 kV, 100%) 1/0 AWG, Compact/Solid, (5 kV, 100%) 1/0 AWG, Stranded, (5 kV, 100%) 1/0-2/0 AWG, Stranded, (5 kV, 100%) 2 AWG, Stranded, (5 kV, 100%) 2-1 AWG, Stranded, (5 kV, 100%) 2/0 AWG, Compact/Solid, (5 kV, 100%) 2/0 AWG, Stranded, (5 kV, 100%) 250 kcmil, Compact/Solid, (5 kV, 100%) 250 kcmil, Stranded, (5 kV, 100%) 3/0 AWG, Compact/Solid, (5 kV, 100%) 3/0 AWG, Stranded, (5 kV, 100%) 3/0 AWG-250 kcmil, Compact/Solid, (5 kV, 100%) 3/0-4/0 AWG, Stranded, (5 kV, 100%) 4/0 AWG, Compact/Solid, (5 kV, 100%) 4/0 AWG, Stranded, (5 kV, 133%) 1 AWG, Compact/Solid, (5 kV, 133%) 1 AWG, Stranded, (5 kV, 133%) 1-1/0 AWG, Stranded, (5 kV, 133%) 1/0 AWG, Compact/Solid, (5 kV, 133%) 1/0 AWG, Stranded, (5 kV, 133%) 2 AWG, Stranded, (5 kV, 133%) 2/0 AWG, Compact/Solid, (5 kV, 133%) 2/0 AWG, Stranded, (5 kV, 133%) 2/0-3/0 AWG, Stranded, (5 kV, 133%) 2/0-4/0 AWG, Compact/Solid, (5 kV, 133%) 250 kcmil, Compact/Solid, (5 kV, 133%) 250 kcmil, Stranded, (5 kV, 133%) 3/0 AWG, Compact/Solid, (5 kV, 133%) 3/0 AWG, Stranded, (5 kV, 133%) 4/0 AWG, Compact/Solid, (5 kV, 133%) 4/0 AWG, Stranded, (5 kV, 133%) 4/0 AWG-250 kcmil, Stranded, (8 kV, 100%) 1 AWG, Compact/Solid, (8 kV, 100%) 1 AWG, Stranded, (8 kV, 100%) 1-1/0 AWG, Stranded, (8 kV, 100%) 1/0 AWG, Compact/Solid, (8 kV, 100%) 1/0 AWG, Stranded, (8 kV, 100%) 2 AWG, Stranded, (8 kV, 100%) 2/0 AWG, Compact/Solid, (8 kV, 100%) 2/0 AWG, Stranded, (8 kV, 100%) 2/0-3/0 AWG, Stranded, (8 kV, 100%) 2/0-4/0 AWG, Compact/Solid, (8 kV, 100%) 250 kcmil, Compact/Solid, (8 kV, 100%) 250 kcmil, Stranded, (8 kV, 100%) 3/0 AWG, Compact/Solid, (8 kV, 100%) 3/0 AWG, Stranded, (8 kV, 100%) 4/0 AWG, Compact/Solid, (8 kV, 100%) 4/0 AWG, Stranded, (8 kV, 100%) 4/0 AWG-250 kcmil, Stranded, (8 kV, 133%) 1 AWG, Stranded, (8 kV, 133%) 1-2/0 AWG, Stranded, (8 kV, 133%) 1/0 AWG, Compact/Solid, (8 kV, 133%) 1/0 AWG, Stranded, (8 kV, 133%) 1/0-3/0 AWG, Compact/Solid, (8 kV, 133%) 2 AWG, Stranded, (8 kV, 133%) 2-1 AWG, Compact/Solid, (8 kV, 133%) 2/0 AWG, Compact/Solid, (8 kV, 133%) 2/0 AWG, Stranded, (8 kV, 133%) 250 kcmil, Compact/Solid, (8 kV, 133%) 250 kcmil, Stranded, (8 kV, 133%) 250 kmcil, Stranded, (8 kV, 133%) 3/0 AWG, Compact/Solid, (8 kV, 133%) 3/0-4/0 AWG, Stranded, (8 kV, 133%) 4/0 AWG, Stranded, (8 kV, 133%) 4/0 AWG-250 kcmil, Compact/Solid
Conductor Sizes
1 AWG, 1/0 AWG, 2 AWG, 2/0 AWG, 250 kcmil, 3/0 AWG, 4 AWG, 4/0 AWG
Current Rating
200 A
Expanded Tube Length (Metric)
19.05 cm
Family
3M™ 200 Amp 5-15 kV Industrial Loadbreak Elbow
Includes Compression Connector
No, Yes
Insulation Diameter Range
0.495-0.585 in, 0.575-0.685 in, 0.630-0.820 in, 0.640-0.760 in, 0.700-0.910 in, 0.785-0.970 in, 0.850-1.100 in, 0.980-1.140 in, 1.040-1.250 in, 1.780-1.965 in
Insulation Diameter Range (Metric)
12.6-14.9 mm, 14.6-17.4 mm, 16.0-20.8 mm, 16.3-19.3 mm, 17.8-23.1 mm, 19.9-24.6 mm, 21.6-27.9 mm, 24.9-29.0 mm, 26.4-31.8 mm, 45.2-49.9 mm
Insulation Level
100%, 133%
Insulation Outside Diameter Range
0.495 to 0.585 in, 0.575 to 0.685 in, 0.63 to 0.82 in, 0.7 to 0.91 in, 0.85 to 1.1 in, 1.04 to 1.25 in
Manufacturing Origin
USA
Maximum Insulation Outer Diameter (Imperial)
0.585 in, 0.685 in, 0.82 in, 0.91 in, 1.1 in, 1.25 in
Maximum Insulation Outer Diameter (Metric)
15 mm, 17 mm, 21 mm, 23 mm, 28 mm, 32 mm
Maximum Operating Voltage
15 kV, 5 kV, 8 kV
Product Type
Accessory
Separable Connector Type
Load Break Elbows
Units per Case
1
Details
  • Ideal for connecting underground cable to transformers, switchgear and junctions that come with loadbreak bushings
  • Cold shrink tube seals from the bottom of the elbow to the cable jacket
  • Specially designed for use on tape shield, wire shield, UniShield® and jacketed concentric neutral types of cables
  • High-quality, peroxide-cured EPDM provides better insulation
  • Meets ANSI/IEEE Standard 386.

3M™ 5810 Series Industrial Loadbreak Elbow Kit is a fully shielded and insulated dead front termination. This kit is for connecting underground cable to transformers, switchgear and junctions that come with loadbreak bushings. It is designed for use on tape shield, wire shield, UniShield® and JCN types of cables. The elbow is peroxide cured EPDM.

3M™ 5810 Series Industrial Loadbreak Elbow Kit includes an elbow body, loadbreak probe, probe installation tool, silicone lubricant, cold shrink jacketing tube, mastic strips, ground braid assembly, constant force spring and CC 3 cable cleaning pads. This kit is rated for 5 to 15 kV, 200 amp applications. Meets ANSI/IEEE Standard 386.

For industrial/occupational use only. Not for consumer sale or use.

3M industrial and occupational products are intended, labeled, and packaged for sale to trained industrial and occupational customers for workplace use.  Unless specifically stated otherwise on the applicable product packaging or literature, these products are not intended, labeled, or packaged for sale to or use by consumers (e.g., for home, personal, primary or secondary school, recreational/sporting, or other uses not described in the applicable product packaging or literature), and must be selected and used in compliance with applicable health and safety regulations and standards (e.g., U.S. OSHA, ANSI), as well as all product literature, user instructions, warnings, and other limitations, and the user must take any action required under any recall, field action, or other product use notice.  Misuse of 3M industrial and occupational products may result in injury, sickness, death, or property damage.  For help with product selection and use, consult your on-site safety professional, industrial hygienist, or other subject matter expert.