1. United States
  2. All 3M Products
  3. Electrical
  4. Power Cable Connectors
  5. Power Cable Terminations
  6. 3M™ Cold Shrink QT-III Termination Kit 7643-T-110, Indoor

3M™ Cold Shrink QT-III Termination Kit 7643-T-110, Indoor

  • Part Number 7643-T-110
  • 3M Product Number 7643-T-110
  • 3M ID 7010396856
  • UPC 00054007417965
Change options
Voltage 5 kV, 8 kV, 15 kV
Conductor Sizes (Imperial) 2/0 AWG, 3/0 AWG, 4/0 AWG, 250 kcmil, 300 kcmil, 350 kcmil, 400 kcmil, 450 kcmil, 500 kcmil
Insulation Outer Diameter (Metric) 16.256 mm, 16.51 mm, 16.764 mm, 17.018 mm, 17.272 mm, 17.526 mm, 17.78 mm, 18.034 mm, 18.288 mm, 18.542 mm, 18.796 mm, 19.05 mm, 19.304 mm, 19.558 mm, 19.812 mm, 20.066 mm, 20.32 mm, 20.574 mm, 20.828 mm, 21.082 mm, 21.336 mm, 21.59 mm, 21.844 mm, 22.098 mm, 22.352 mm, 22.606 mm, 22.86 mm, 23.114 mm, 23.368 mm, 23.622 mm, 23.876 mm, 24.13 mm, 24.384 mm, 24.638 mm, 24.892 mm, 25.146 mm, 25.4 mm, 25.654 mm, 25.908 mm, 26.162 mm, 26.416 mm, 26.67 mm, 26.924 mm, 27.178 mm, 27.432 mm
Breakout Boot No
Insulation Outer Diameter (Imperial) 0.72 in, 0.73 in, 0.74 in, 0.75 in, 0.76 in, 0.77 in, 0.78 in, 0.79 in, 0.8 in, 0.81 in, 0.82 in, 0.83 in, 0.84 in, 0.85 in, 0.86 in, 0.87 in, 0.88 in, 0.89 in, 0.9 in, 0.91 in, 0.92 in, 0.93 in, 0.94 in, 0.95 in, 0.96 in, 0.97 in, 0.98 in, 0.99 in, 1 in, 1.01 in, 1.02 in, 1.03 in, 1.04 in, 1.05 in, 1.06 in, 1.07 in, 1.08 in, 1.09 in, 1.1 in, 1.11 in, 1.12 in, 1.13 in, 1.14 in, 1.15 in, 1.16 in, 1.17 in, 1.18 in, 1.19 in, 1.2 in, 1.21 in, 1.22 in, 1.23 in, 1.24 in, 1.25 in, 1.26 in, 1.27 in, 1.28 in, 1.29 in
Cable Shielding Concentric Neutral (CN), Jacketed Concentric Neutral (JCN)

RELIABLE PERFORMANCE: Provides a void-free seal on jacketed concentric neutral and concentric neutral power cables

SPECIFICALLY FORMULATED: Made with high dielectric-constant material that helps control the electrical field stress distribution

ENGINEERED TO LAST: Built tough with non-tracking, molded, silicone rubber insulation

View more details
Frequently viewed resources
Tech Data Sheet (PDF, 236KB)

Details

Highlights

  • RELIABLE PERFORMANCE: Provides a void-free seal on jacketed concentric neutral and concentric neutral power cables
  • SPECIFICALLY FORMULATED: Made with high dielectric-constant material that helps control the electrical field stress distribution
  • ENGINEERED TO LAST: Built tough with non-tracking, molded, silicone rubber insulation
  • INTENDED USE: Ideal for indoor applications
  • EASY INSTALLATION: Conforms in restricted environments where space is limited
  • SPECIFICATIONS: Meets or exceeds IEEE Standard 48, Class 1 requirements for 5, 8, 15, 25/28, and 35 kV terminations
  • KIT CONTENTS: Items vary between kits — for detailed kit contents please refer to the product catalog

3M™ Cold Shrink QT-III Termination Kit 7620-T, 7620-S, 7640-T, 7650-T, 7680-S, and 7690-T Series are designed for indoor use to control the electrical field stress distribution and help promote a void-free seal on jacketed concentric neutral power cables. These kits are made with non-tracking silicone rubber insulation, providing a secure seal and long-lasting durability. The robust construction includes high dielectric-constant material and silicone rubber insulation. Cold shrink technology helps facilitate a simple installation, eliminating the need for force-fitting and promoting adaptation to confined workspaces. These kits are engineered to meet varying voltage requirements ranging from 5 to 35 kV. For comprehensive technical information about a specific product in this series, please consult a 3M expert.

Relying on science-based performance, 3M™ Cold Shrink QT-III Termination Kit 7620-T, 7620-S, 7640-T, 7650-T, 7680-S, and 7690-T Series provide electrical solutions that help meet your needs and promote efficient operations. 3M is committed to providing dependable electrical products that address everyday challenges in the field. Pioneered by 3M and implemented globally, cold shrink technology helps speed up production without sacrificing performance because operations take less time and can be performed without a heating source. This product family delivers long-lasting performance and simple installation, helping you keep your operations on schedule.

Typical properties

Resources

Similar products

Voltage 5 kV, 8 kV, 15 kV
Conductor Sizes (Imperial) 2/0 AWG, 3/0 AWG, 4/0 AWG, 250 kcmil, 300 kcmil, 350 kcmil, 400 kcmil, 450 kcmil, 500 kcmil
Insulation Outer Diameter (Metric) 16.256 mm, 16.51 mm, 16.764 mm, 17.018 mm, 17.272 mm, 17.526 mm, 17.78 mm, 18.034 mm, 18.288 mm, 18.542 mm, 18.796 mm, 19.05 mm, 19.304 mm, 19.558 mm, 19.812 mm, 20.066 mm, 20.32 mm, 20.574 mm, 20.828 mm, 21.082 mm, 21.336 mm, 21.59 mm, 21.844 mm, 22.098 mm, 22.352 mm, 22.606 mm, 22.86 mm, 23.114 mm, 23.368 mm, 23.622 mm, 23.876 mm, 24.13 mm, 24.384 mm, 24.638 mm, 24.892 mm, 25.146 mm, 25.4 mm, 25.654 mm, 25.908 mm, 26.162 mm, 26.416 mm, 26.67 mm, 26.924 mm, 27.178 mm, 27.432 mm
Breakout Boot No
Insulation Outer Diameter (Imperial) 0.72 in, 0.73 in, 0.74 in, 0.75 in, 0.76 in, 0.77 in, 0.78 in, 0.79 in, 0.8 in, 0.81 in, 0.82 in, 0.83 in, 0.84 in, 0.85 in, 0.86 in, 0.87 in, 0.88 in, 0.89 in, 0.9 in, 0.91 in, 0.92 in, 0.93 in, 0.94 in, 0.95 in, 0.96 in, 0.97 in, 0.98 in, 0.99 in, 1 in, 1.01 in, 1.02 in, 1.03 in, 1.04 in, 1.05 in, 1.06 in, 1.07 in, 1.08 in, 1.09 in, 1.1 in, 1.11 in, 1.12 in, 1.13 in, 1.14 in, 1.15 in, 1.16 in, 1.17 in, 1.18 in, 1.19 in, 1.2 in, 1.21 in, 1.22 in, 1.23 in, 1.24 in, 1.25 in, 1.26 in, 1.27 in, 1.28 in, 1.29 in
Cable Shielding Concentric Neutral (CN), Jacketed Concentric Neutral (JCN)

For industrial/occupational use only. Not for consumer sale or use.

3M industrial and occupational products are intended, labeled, and packaged for sale to trained industrial and occupational customers for workplace use.  Unless specifically stated otherwise on the applicable product packaging or literature, these products are not intended, labeled, or packaged for sale to or use by consumers (e.g., for home, personal, primary or secondary school, recreational/sporting, or other uses not described in the applicable product packaging or literature), and must be selected and used in compliance with applicable health and safety regulations and standards (e.g., U.S. OSHA, ANSI), as well as all product literature, user instructions, warnings, and other limitations, and the user must take any action required under any recall, field action, or other product use notice.  Misuse of 3M industrial and occupational products may result in injury, sickness, death, or property damage.  For help with product selection and use, consult your on-site safety professional, industrial hygienist, or other subject matter expert.