3M™ Cold Shrink QT-II Outdoor Termination Kit 5608, CN Shielding, 15-35 kV, 1.80-2.75 in (46-70 mm) Cable Insul. O.D., 1/kit

Part Number 56083M ID 7000140712UPC 50054007091689
  • One-piece cold shrink termination.
  • High dielectric-constant material regulates the distribution of electric field stress
  • Suitable for outdoor, weather exposed applications
  • Silicone rubber insulation is track-resistance and hydrophobic
 More...
View all details
View Legal Disclaimer
For industrial/occupational use only. Not for consumer sale or use.
Specifications
Attribute Name
Value
Brand
3M™
Breakout Boot
No
Cable Insulation Outside Diameter Range
1.80-2.75 in
Cable Insulation Outside Diameter Range (Metric)
45.7-69.8 mm
Cable Shielding
Concentric Neutral (CN)
Case Quantity
1
Conductor Sizes (Imperial)
1000 kcmil, 1250 kcmil, 1500 kcmil, 1750 kcmil, 2000 kcmil
Family
QT-II
Indoor/Outdoor
Outdoor Skirted
Insulation Level
100%, 133%
Insulation Outer Diameter (Imperial)
1.8 in, 1.81 in, 1.82 in, 1.83 in, 1.84 in, 1.85 in, 1.86 in, 1.87 in, 1.88 in, 1.89 in, 1.9 in, 1.91 in, 1.92 in, 1.93 in, 1.94 in, 1.95 in, 1.96 in, 1.97 in, 1.98 in, 1.99 in, 2 in, 2.01 in, 2.02 in, 2.03 in, 2.04 in, 2.05 in, 2.06 in, 2.07 in, 2.08 in, 2.09 in, 2.1 in, 2.11 in, 2.12 in, 2.13 in, 2.14 in, 2.15 in, 2.16 in, 2.17 in, 2.18 in, 2.19 in, 2.2 in, 2.21 in, 2.22 in, 2.23 in, 2.24 in, 2.25 in, 2.26 in, 2.27 in, 2.28 in, 2.29 in, 2.3 in, 2.31 in, 2.32 in, 2.33 in, 2.34 in, 2.35 in, 2.36 in, 2.37 in, 2.38 in, 2.39 in, 2.4 in, 2.41 in, 2.42 in, 2.43 in, 2.44 in, 2.45 in, 2.46 in, 2.47 in, 2.48 in, 2.49 in, 2.5 in, 2.51 in, 2.52 in, 2.53 in, 2.54 in, 2.55 in, 2.56 in, 2.57 in, 2.58 in, 2.59 in, 2.6 in, 2.61 in, 2.62 in, 2.63 in, 2.64 in, 2.65 in, 2.66 in, 2.67 in, 2.68 in, 2.69 in, 2.7 in, 2.71 in, 2.72 in, 2.73 in, 2.74 in, 2.75 in
Insulation Outer Diameter (Metric)
45.72 mm, 45.974 mm, 46.228 mm, 46.482 mm, 46.736 mm, 46.99 mm, 47.244 mm, 47.498 mm, 47.752 mm, 48.006 mm, 48.26 mm, 48.514 mm, 48.768 mm, 49.022 mm, 49.276 mm, 49.53 mm, 49.784 mm, 50.038 mm, 50.292 mm, 50.546 mm, 50.8 mm, 51.054 mm, 51.308 mm, 51.562 mm, 51.816 mm, 52.07 mm, 52.324 mm, 52.578 mm, 52.832 mm, 53.086 mm, 53.34 mm, 53.594 mm, 53.848 mm, 54.102 mm, 54.356 mm, 54.61 mm, 54.864 mm, 55.118 mm, 55.372 mm, 55.626 mm, 55.88 mm, 56.134 mm, 56.388 mm, 56.642 mm, 56.896 mm, 57.15 mm, 57.404 mm, 57.658 mm, 57.912 mm, 58.166 mm, 58.42 mm, 58.674 mm, 58.928 mm, 59.182 mm, 59.436 mm, 59.69 mm, 59.944 mm, 60.198 mm, 60.452 mm, 60.706 mm, 60.96 mm, 61.214 mm, 61.468 mm, 61.722 mm, 61.976 mm, 62.23 mm, 62.484 mm, 62.738 mm, 62.992 mm, 63.246 mm, 63.5 mm, 63.754 mm, 64.008 mm, 64.262 mm, 64.516 mm, 64.77 mm, 65.024 mm, 65.278 mm, 65.532 mm, 65.786 mm, 66.04 mm, 66.294 mm, 66.548 mm, 66.802 mm, 67.056 mm, 67.31 mm, 67.564 mm, 67.818 mm, 68.072 mm, 68.326 mm, 68.58 mm, 68.834 mm, 69.088 mm, 69.342 mm, 69.596 mm, 69.85 mm
Insulation Rejacketing
No
Lug/Stem Connector Included in Kit
No
Maximum Installed Length
19.50 in
Number of Conductors
1
Number of Skirts
8
PlantAnalystID
ABBA-Z1GUQ
Product Series
5680
RoHS 2011/65/EU Compliant
Undetermined
RoHS EU Comments
Contact 3M for information
Voltage
15 kV, 25 kV, 35 kV
Details
  • One-piece cold shrink termination.
  • High dielectric-constant material regulates the distribution of electric field stress
  • Suitable for outdoor, weather exposed applications
  • Silicone rubber insulation is track-resistance and hydrophobic
  • Silicone cold shrink application provides constant radial pressure, "living seal"
  • Withstands voltages of 5 to 15kV and is 110 kV BIL-rated
  • Meets IEEE Standard 48, Class 1 for outdoor, weather-exposed applications

3M™ Cold Shrink QT II 5600 & 5680 Series Termination Kit includes a 4 skirt, 1 piece termination. It ensures a pliable, tight seal for concentric neutral cables. The conjunction of high dielectric constant material and silicone rubber insulation allows the termination to withstand voltages of 5 to 15kV.

Legal Disclaimer

Manufacturing Origin: USA

The designation that a product is Manufactured in the USA means the product undergoes substantial transformation in one of our U.S. Manufacturing plants. Some products contain imported components.

Note: 3M products offered on a government contract that require country of origin representation must be certified by 3M Trade Compliance. Contact customer service at 800-245-3573 to request a certificate.

For industrial/occupational use only. Not for consumer sale or use.

3M industrial and occupational products are intended, labeled, and packaged for sale to trained industrial and occupational customers for workplace use.  Unless specifically stated otherwise on the applicable product packaging or literature, these products are not intended, labeled, or packaged for sale to or use by consumers (e.g., for home, personal, primary or secondary school, recreational/sporting, or other uses not described in the applicable product packaging or literature), and must be selected and used in compliance with applicable health and safety regulations and standards (e.g., U.S. OSHA, ANSI), as well as all product literature, user instructions, warnings, and other limitations, and the user must take any action required under any recall, field action, or other product use notice.  Misuse of 3M industrial and occupational products may result in injury, sickness, death, or property damage.  For help with product selection and use, consult your on-site safety professional, industrial hygienist, or other subject matter expert.