  6. 3M™ Molded Rubber QS Inline JCN/CN Splice Kits 5400 Series

3M™ Molded Rubber QS Inline JCN/CN Splice Kits 5400 Series

  • Inline splice to use on jacketed concentric neutral (JCN) or concentric neutral (CN) cables
  • Rated for 15 kV cables
  • Meets the requirements of IEEE 404 standards for cable joints
 More...
View all details
For industrial/occupational use only. Not for consumer sale or use.
All Options
Close
Specifications
Attribute Name
Value
Brand
3M™
Cable Shielding
Concentric Neutral (CN), Jacketed Concentric Neutral (JCN)
Case Quantity
1
Conductor Material
Aluminum, Copper
Connector Included
CI-350, CI-500, CI-750, None
Insulation O.D. Range
1.060 - 1.210 Inch, 1.120 - 1.320 Inch, 1.320 - 1.520 Inch
Insulation Outer Diameter (Imperial)
1.06 in, 1.07 in, 1.08 in, 1.09 in, 1.1 in, 1.11 in, 1.12 in, 1.13 in, 1.14 in, 1.15 in, 1.16 in, 1.17 in, 1.18 in, 1.19 in, 1.2 in, 1.21 in, 1.22 in, 1.23 in, 1.24 in, 1.25 in, 1.26 in, 1.27 in, 1.28 in, 1.29 in, 1.3 in, 1.31 in, 1.32 in, 1.33 in, 1.34 in, 1.35 in, 1.36 in, 1.37 in, 1.38 in, 1.39 in, 1.4 in, 1.41 in, 1.42 in, 1.43 in, 1.44 in, 1.45 in, 1.46 in, 1.47 in, 1.48 in, 1.49 in, 1.5 in, 1.51 in, 1.52 in
Insulation Outer Diameter (Metric)
26.924 mm, 27.178 mm, 27.432 mm, 27.686 mm, 27.94 mm, 28.194 mm, 28.448 mm, 28.702 mm, 28.956 mm, 29.21 mm, 29.464 mm, 29.718 mm, 29.972 mm, 30.226 mm, 30.48 mm, 30.734 mm, 30.988 mm, 31.242 mm, 31.496 mm, 31.75 mm, 32.004 mm, 32.258 mm, 32.512 mm, 32.766 mm, 33.02 mm, 33.274 mm, 33.528 mm, 33.782 mm, 34.036 mm, 34.29 mm, 34.544 mm, 34.798 mm, 35.052 mm, 35.306 mm, 35.56 mm, 35.814 mm, 36.068 mm, 36.322 mm, 36.576 mm, 36.83 mm, 37.084 mm, 37.338 mm, 37.592 mm, 37.846 mm, 38.1 mm, 38.354 mm, 38.608 mm
Insulation Outside Diameter Range
1.060 - 1.210 Inch, 1.120 - 1.320 Inch, 1.320 - 1.520 Inch
Insulation Outside Diameter Range (Metric)
26.9 - 30.7 mm, 28.5 - 33.5 mm, 33.5 - 38.6 mm
Manufacturing Origin
USA
Maximum Conductor Size (Imperial)
250 kcmil (Stranded), 350 kcmil (Stranded), 500 kcmil (Stranded), 750 kcmil (Stranded)
Number of Conductors
1
Operating Voltage
15 kV
Product Type
Inline
Splice Type
Inline
Voltage
25/28 kV
Details
  • Inline splice to use on jacketed concentric neutral (JCN) or concentric neutral (CN) cables
  • Rated for 15 kV cables
  • Meets the requirements of IEEE 404 standards for cable joints

3M™ Molded Rubber QS Inline JCN/CN Splice Kits 5400 Series are inline splices designed for use on 15 kV concentric neutral (CN) or jacketed concentric neutral (JCN) cable. The continuous current rating of each splice is equal to the current rating of the cable it is sized to accommodate. Meets requirements of IEEE 404 for cable joints. Jacketing kit is needed for JCN cable. Each kit makes one splice. Connectors, unless specified, are not included in the kit, and must be ordered separately. Note: Cable sizes shown below are for standard insulation thickness. Final determining factor is cable insulation O.D.

For industrial/occupational use only. Not for consumer sale or use.

3M industrial and occupational products are intended, labeled, and packaged for sale to trained industrial and occupational customers for workplace use.  Unless specifically stated otherwise on the applicable product packaging or literature, these products are not intended, labeled, or packaged for sale to or use by consumers (e.g., for home, personal, primary or secondary school, recreational/sporting, or other uses not described in the applicable product packaging or literature), and must be selected and used in compliance with applicable health and safety regulations and standards (e.g., U.S. OSHA, ANSI), as well as all product literature, user instructions, warnings, and other limitations, and the user must take any action required under any recall, field action, or other product use notice.  Misuse of 3M industrial and occupational products may result in injury, sickness, death, or property damage.  For help with product selection and use, consult your on-site safety professional, industrial hygienist, or other subject matter expert.