1. United States
  2. All 3M Products
  3. Electrical
  4. Power Cable Connectors
  5. Power Cable Terminations
  6. 3M™ Cold Shrink QT-III Termination Kit 7655-S-4-TI, Tape, Wire, UniShield®, 5-25/28 kV, Insulation OD 1.05-1.80 in, 4 Skirt, 1/kit

3M™ Cold Shrink QT-III Termination Kit 7655-S-4-TI, Tape, Wire, UniShield®, 5-25/28 kV, Insulation OD 1.05-1.80 in, 4 Skirt, 1/kit

Part Number 7655-S-4-TI3M ID 80611200116UPC 00054007434122
  • Provides a void-free seal to jacketed concentric neutral and concentric neutral power cables
  • High dielectric-constant material regulates the distribution of electric field stress
  • Suitable for outdoor applications
  • Integrated, jumper wire-top insulator and step-core design allows for easier installation, while sealing compounds provide constant radial pressure
 More...
View all details
For industrial/occupational use only. Not for consumer sale or use.
Specifications
Attribute Name
Value
Brand
3M™
Breakout Boot
No
Cable Insulation Outside Diameter Range
1.05-1.80 in
Cable Insulation Outside Diameter Range (Metric)
26.7-45.7 mm
Cable Shielding
Concentric Neutral (CN), Jacketed Concentric Neutral (JCN)
Case Quantity
1
Compatible Lug
QL2-A-350-750, QL2-A-4/0-600
Conductor Sizes (Imperial)
1000 kcmil, 1250 kcmil, 1500 kcmil, 250 kcmil, 300 kcmil, 350 kcmil, 400 kcmil, 450 kcmil, 500 kcmil, 600 kcmil, 700 kcmil, 750 kcmil, 800 kcmil, 900 kcmil
Family
QT-III
Indoor/Outdoor
Outdoor Skirted
Insulation Level
100%, 133%
Insulation Outer Diameter (Imperial)
1.05 in, 1.06 in, 1.07 in, 1.08 in, 1.09 in, 1.1 in, 1.11 in, 1.12 in, 1.13 in, 1.14 in, 1.15 in, 1.16 in, 1.17 in, 1.18 in, 1.19 in, 1.2 in, 1.21 in, 1.22 in, 1.23 in, 1.24 in, 1.25 in, 1.26 in, 1.27 in, 1.28 in, 1.29 in, 1.3 in, 1.31 in, 1.32 in, 1.33 in, 1.34 in, 1.35 in, 1.36 in, 1.37 in, 1.38 in, 1.39 in, 1.4 in, 1.41 in, 1.42 in, 1.43 in, 1.44 in, 1.45 in, 1.46 in, 1.47 in, 1.48 in, 1.49 in, 1.5 in, 1.51 in, 1.52 in, 1.53 in, 1.54 in, 1.55 in, 1.56 in, 1.57 in, 1.58 in, 1.59 in, 1.6 in, 1.61 in, 1.62 in, 1.63 in, 1.64 in, 1.65 in, 1.66 in, 1.67 in, 1.68 in, 1.69 in, 1.7 in, 1.71 in, 1.72 in, 1.73 in, 1.74 in, 1.75 in, 1.76 in, 1.77 in, 1.78 in, 1.79 in, 1.8 in
Insulation Outer Diameter (Metric)
11.684 mm, 26.67 mm, 26.924 mm, 27.178 mm, 27.432 mm, 27.686 mm, 27.94 mm, 28.194 mm, 28.448 mm, 28.702 mm, 28.956 mm, 29.21 mm, 29.464 mm, 29.718 mm, 29.972 mm, 30.226 mm, 30.48 mm, 30.734 mm, 30.988 mm, 31.242 mm, 31.496 mm, 31.75 mm, 32.004 mm, 32.258 mm, 32.512 mm, 32.766 mm, 33.02 mm, 33.274 mm, 33.528 mm, 33.782 mm, 34.036 mm, 34.29 mm, 34.544 mm, 34.798 mm, 35.052 mm, 35.306 mm, 35.56 mm, 35.814 mm, 36.068 mm, 36.322 mm, 36.576 mm, 36.83 mm, 37.084 mm, 37.338 mm, 37.592 mm, 37.846 mm, 38.1 mm, 38.354 mm, 38.608 mm, 38.862 mm, 39.116 mm, 39.37 mm, 39.624 mm, 39.878 mm, 40.132 mm, 40.386 mm, 40.64 mm, 40.894 mm, 41.148 mm, 41.402 mm, 41.656 mm, 41.91 mm, 42.164 mm, 42.418 mm, 42.672 mm, 42.926 mm, 43.18 mm, 43.434 mm, 43.688 mm, 43.942 mm, 44.196 mm, 44.45 mm, 44.704 mm, 44.958 mm, 45.212 mm, 45.466 mm, 45.72 mm
Insulation Rejacketing
No
Jacket Outside Diameter Range
1.39-2.40 Inch
Jacket Outside Diameter Range (Metric)
35.3-61.0 mm
Lug/Stem Connector Included in Kit
No
Maximum Installed Length
12.25 in
Number of Conductors
1
Number of Skirts
4
Voltage
15 kV, 25 kV, 5 kV, 8 kV
Details
  • Provides a void-free seal to jacketed concentric neutral and concentric neutral power cables
  • High dielectric-constant material regulates the distribution of electric field stress
  • Suitable for outdoor applications
  • Integrated, jumper wire-top insulator and step-core design allows for easier installation, while sealing compounds provide constant radial pressure

3M™ Cold Shrink QT III 7640 S & 7650 S Series Termination Kit includes a skirted termination with a jumper wire top insulator. It ensures a pliable, tight seal for jacketed concentric neutral and concentric neutral power cables. The conjunction of high dielectric constant material and sealing compounds allows the termination to withstand voltages of 5 to 25/28 kV.

For industrial/occupational use only. Not for consumer sale or use.

3M industrial and occupational products are intended, labeled, and packaged for sale to trained industrial and occupational customers for workplace use.  Unless specifically stated otherwise on the applicable product packaging or literature, these products are not intended, labeled, or packaged for sale to or use by consumers (e.g., for home, personal, primary or secondary school, recreational/sporting, or other uses not described in the applicable product packaging or literature), and must be selected and used in compliance with applicable health and safety regulations and standards (e.g., U.S. OSHA, ANSI), as well as all product literature, user instructions, warnings, and other limitations, and the user must take any action required under any recall, field action, or other product use notice.  Misuse of 3M industrial and occupational products may result in injury, sickness, death, or property damage.  For help with product selection and use, consult your on-site safety professional, industrial hygienist, or other subject matter expert.