Attribute Name
|
Value
|
---|---|
Brand
|
3M™
|
Cable Outside Diameter (Metric)
|
19 mm
|
Cable Shielding
|
Non-shielded
|
Cable Type
|
Power Cable
|
Color Family
|
Black
|
Conductor Material
|
Aluminum, Copper
|
Conductor Sizes (Imperial)
|
2 AWG
|
Connector Included
|
No
|
Connector Maximum Outside Diameter
|
0.687 in
|
Connector Maximum Outside Diameter (Metric)
|
17.0 mm
|
Dielectric Strength (V/mil)
|
365 V/mil
|
Elongation
|
750 %
|
Indoor/Outdoor
|
Both
|
Insulation O.D. Range
|
0.20-0.75 in
|
Insulation O.D. Range (Metric)
|
5-19 mm
|
Insulation Outer Diameter (Imperial)
|
0.2 in, 0.21 in, 0.22 in, 0.23 in, 0.24 in, 0.25 in, 0.26 in, 0.27 in, 0.28 in, 0.29 in, 0.3 in, 0.31 in, 0.32 in, 0.33 in, 0.34 in, 0.35 in, 0.36 in, 0.37 in, 0.38 in, 0.39 in, 0.4 in, 0.41 in, 0.42 in, 0.43 in, 0.44 in, 0.45 in, 0.46 in, 0.47 in, 0.48 in, 0.49 in, 0.5 in, 0.51 in, 0.52 in, 0.53 in, 0.54 in, 0.55 in, 0.56 in, 0.57 in, 0.58 in, 0.59 in, 0.6 in, 0.61 in, 0.62 in, 0.63 in, 0.64 in, 0.65 in, 0.66 in, 0.67 in, 0.68 in, 0.69 in, 0.7 in, 0.71 in, 0.72 in, 0.73 in, 0.74 in, 0.75 in
|
Insulation Outer Diameter (Metric)
|
10.16 mm, 10.414 mm, 10.668 mm, 10.922 mm, 11.176 mm, 11.43 mm, 11.684 mm, 11.938 mm, 12.192 mm, 12.446 mm, 12.7 mm, 12.954 mm, 13.208 mm, 13.462 mm, 13.716 mm, 13.97 mm, 14.224 mm, 14.478 mm, 14.732 mm, 14.986 mm, 15.24 mm, 15.494 mm, 15.748 mm, 16.002 mm, 16.256 mm, 16.51 mm, 16.764 mm, 17.018 mm, 17.272 mm, 17.526 mm, 17.78 mm, 18.034 mm, 18.288 mm, 18.542 mm, 18.796 mm, 19.05 mm, 5.08 mm, 5.334 mm, 5.588 mm, 5.842 mm, 6.096 mm, 6.35 mm, 6.604 mm, 6.858 mm, 7.112 mm, 7.366 mm, 7.62 mm, 7.874 mm, 8.128 mm, 8.382 mm, 8.636 mm, 8.89 mm, 9.144 mm, 9.398 mm, 9.652 mm, 9.906 mm
|
Manufacturing Origin
|
USA
|
Maximum Conductor Size (Imperial)
|
2/0 AWG
|
Maximum Connector Length
|
2.50 in
|
Maximum Connector Length (Metric)
|
63 mm
|
Maximum Connector O.D.
|
0.687 in
|
Maximum Connector O.D. (Metric)
|
17 mm
|
Minimum Conductor Size (Imperial)
|
8 AWG
|
Model
|
Cold Shrink
|
Number of Conductors
|
3
|
Product Color
|
Black
|
Splice Type
|
Inline
|
Voltage
|
1 kV
|
Voltage Rating
|
0.6/1 kV
|
3M™ Cold Shrink Quick Splice Low Voltage QSLV-M are open-ended tubular rubber sleeves with sealing mastic on each end which are factory expanded and assembled onto a unique three-core system. Two cores, one on each end, are removed after the QSLV-M insulator has been centered over an inline connector, allowing the ends of the tube to shrink and form a water-resistant seal. The third, center segment of the core remains inside the cold shrink tube, acting as a support structure. Sizing of the cores and tube, along with the sealing mastic on each end, is designed to accommodate the variance in connectors and connector crimping techniques and final dimensions without degrading the seal and insulating characteristics of the EPDM rubber tube, while also making core removal easy. Two diameter sizes will cover a range of 1 kV or less cable from 8 AWG through 1000 kcmil for copper and 8 AWG through 500 kcmil for aluminum conductors with crimped connectors. In aerial applications where intense UV radiation will be common and visual inspection is not possible, it is recommended to overwrap the tubing with Scotch® Super 33+™ Vinyl Electrical Tape or Scotch® Self-Fusing Silicone Rubber Electrical Tape 70. Note: Insulator may be used on cable sizes outside of the recommended range provided both cables are within the insulation O.D. range, and the connector meets the dimensional requirements shown in the table.