Your form was submitted successfully!
An error has occurred while submitting. Please try again later...
The pharmaceutical industry requires high water quality without contamination. 3M™ Liqui-Cel™ Membrane Contactors offer an ideal solution for reliable and efficient gas control with low extractables.*
Unlike conventional Forced Draft Deaerators or chemical alternatives 3M Liqui-Cel are closed systems that may help reduce the risk of introducing environmental contaminants and they do not require chemicals to operate.
Additionally, EDI and CDI technology have become commonplace for ion exchange in the pharmaceutical industry. These technologies operate more efficiently if the dissolved CO₂ is first removed from the water. High CO₂ level in the water could reduce the efficiency of the EDI units requiring the installation of more EDI stacks than are necessary.
3M™ Liqui-Cel™ Membrane Contactors are compact and reliable devices that are able to reduce CO₂ levels down <1 ppm. For more than a decade, these gas transfer membrane have been used in pharmaceutical process water applications to keep dissolved gases in process water in check.
*3M™ Liqui-Cel™ Membrane Contactors may be used to create the purified water that is processed by either distillation or some other equivalent process to create WFI. 3M™ Liqui-Cel™ Membrane Contactors should not be used during the production of the WFI after the distillation or other equivalent process
(SPEECH) [NO SPEECH] (DESCRIPTION) Logo, 3M. Liqui-Cel Membrane Contactors. Advanced Dissolved Gas Control. EXF Series 10x28 Membrane Contractor. How It Works. 2017 3M Company. All rights reserved. 3M and Liqui-Cel are trademarks of 3M Company. 3M.com slash Liqui-Cel. Stainless Steel Housing. Flow Range: 10 to 57 m3 per hour. (44 to 250 gpm.) Liquid Inlet with Dissolved Gas and animation of gas flowing from the inlet through the cylinder and out through the Liquid Outlet at the top. Text, Sweep Gas, C O 2 slash N 2 (optional). Gas enters through the top curved pipe. Text, Vacuum (optional). The gas exits through the bottom curved pipe. Text, Hollow Fiber Membrane - Liquid slash Gas Transfer. An illustration in a rectangular box. Arrows point in one direction on the sides of the internal tube. Text, Water is in transverse flow across a bank of hollow fibers. Gases in the atmosphere dissolve into water until equilibrium is reached. Equilibrium between the liquid and gas phase is offset when a vacuum and/or source of strip gas is applied. This creates a driving force to move gases from the liquid phase into the gas phase. Logo, 3M. Liqui-Cel Membrane Contactors. Advanced Dissolved Gas Control. 3M dot com slash Liqui-Cel.
EXF Series Datasheets
SP Series Datasheets
2x6 Product Drawings
2.5x8 Product Drawings
4x13 Product Drawings
4x28 Product Drawings
6x28 Product Drawings
8x20 Product Drawings
10x28 Product Drawings
14x28 Product Drawings
3M Deutschland GmbH
Öhder Straße 28
42289 Wuppertal Germany
Phone: +49 202 6099 -0
Fax: +49 202 6099 - 750
3M Deutschland GmbH
Öhder Straße 28
42289 Wuppertal Germany
Phone: +49 202 6099 -0
Fax: +49 202 6099 - 750