Bubbles and dissolved gases can have negative impacts on instrument measurement accuracies and reliabilities in many analyzers. Bubbles and gases can also alter the composition of a solution being analyzed. Since time is valuable to laboratory and research center personnel, removing dissolved gas may help improve reliability and prevent inaccurate analyzer readings or altered solution composition that require tests to be repeated.
Quality control steps in production processes may also require degassing to reduce the risk of bubbles registering as defects . Depending on flow rates and solution composition, 3M™ Liqui-Cel™ Membrane Contactors may be able to reduce or eliminate bubbles in your process to reduce waste associated with discarding good product.
Compact 3M™ Liqui-Cel™ Membrane Contactors can be installed in-line and use minimal space for easy integration into lab equipment, analyzers or DI water systems analyzing solutions. The MM series is suited for very low flow rates in lab-scale environment while EXF series membrane contactors are designed to handle larger pure water flows. For solutions with low surface tensions the SP series may be the solution you need.
(SPEECH) [NO SPEECH] (DESCRIPTION) Text, 3M. Liqui-Cel Membrane Contactors. Debubbling for Lab/Analytical Applications. MM Series. How It Works. MM Series Membrane Contactors. Available in 3 sizes: MM Series 1 by 5.5. Up to 500ml/min. MM Series 1.7 by 5.5. Up to 2500ml/min. MM Series 1.7 by 8.75. Up to 3000ml/min. Liquid Inlet with Dissolved Gas. Liquid Outlet. Hollow Fiber Membrane. Vacuum Phase with Removed Gases. The liquid flows on the inside of the hollow fibers in this design. These contactors are used for small flow rates up to 3000 ml/min. They are typically used in vacuum only operations. Water flows through a tube in the middle of a filter with two holes on top. Text, 3M. Liqui-Cel Membrane Contactors. Debubbling for Lab/Analytical Applications. 3M.com/Liqui-Cel.
EXF Series Datasheets
MM Series Datasheets
SP Series Datasheets
0.5x1 Product Drawings
1x3 Product Drawings
1x5.5 Product Drawings
1.7x5.5 Product Drawings
1.7x8.75 Product Drawings
2x6 Product Drawings
2.5x8 Product Drawings
4x13 Product Drawings
4x28 Product Drawings
14x28 Product Drawings
3M Separation and Purification
Sciences Division
13840 South Lakes Dr.
Charlotte, NC 28273 USA
Phone: + 1 980 859 5400
Fax: + 1 980 859 5258
3M Separation and Purification
Sciences Division
13840 South Lakes Dr.
Charlotte, NC 28273 USA
Phone: + 1 980 859 5400
Fax: + 1 980 859 5258
3M Deutschland GmbH
Öhder Straße 28
42289 Wuppertal Germany
Phone: +49 202 6099 - 0
Fax: +49 202 6099 - 750
3M Deutschland GmbH
Öhder Straße 28
42289 Wuppertal Germany
Phone: +49 202 6099 - 0
Fax: +49 202 6099 - 750