1. All 3M Products
  • Scotch® Tape Termination Kit 5700 Series
  • Scotch® Tape Termination Kit 5700 Series

    • Terminates solid dielectric shielded power cables rated 5 to 15 kV
    • Withstands voltages from 5 to 15 kV
    • Comes with sufficient materials to make 3 terminations
     More...
    All Options
    Close
    Specifications
    Attribute Name
    Value
    Agency Approvals
    IEEE
    Application
    Cable Termination
    Brand
    Scotch®, Scotch™
    Cable Shielding
    Concentric Neutral (CN), Tape Shield, UniShield®, Wire Shield
    Cable Size Range
    1500-3000 kcmil
    Cable Type
    Concentric Neutral (CN)
    Case Quantity
    3
    Conductor Size by Voltage
    (15 kV) 800-1000 kcmil, (25/28 kV) 800-1000 kcmil, (5 kV) 8-4/0 AWG, (8 kV) 8-4/0 AWG, (15 kV) 8-4/0 AWG
    Conductor Size Range
    8 - 4/0 AWG, 800 - 1000 kcmil
    Conductor Sizes
    1 AWG, 4/0 AWG, 2/0 AWG, 4 AWG, 1/0 AWG, 6 AWG, 2 AWG, 8 AWG, 3/0 AWG, 1000 kcmil, 250 kcmil, 300 kcmil, 350 kcmil, 400 kcmil, 500 kcmil, 600 kcmil, 700 kcmil, 750 kcmil, 800 kcmil, 900 kcmil
    Family
    Tape Termination Kits
    Indoor/Outdoor
    Indoor
    Insulation Level
    1, 100%, 133%
    Insulation Rejacketing
    No
    Lug/Stem Connector Included in Kit
    No
    Manufacturing Origin
    USA
    Maximum Installed Length
    (Concentric Neutral, 15 kV) 18.50 in, (Concentric Neutral, 5 kV) 11.25 in, (Concentric Neutral, 8 kV) 13.50 in, (UniShield®, 15 kV) 18.50 in, (UniShield®, 5 kV) 11.25 in, (UniShield®, 8 kV) 13.50 in, (Wire Shielded Cable, 15 kV) 20.00 in, (Wire Shielded Cable, 5 kV) 12.75 in, (Wire Shielded Cable, 8 kV) 15.00 in, Wire Shielded Cable: 15 kV: 20 in/Unishield: 15 kV: 18.5 in/Concentric Neutral: 15 kV: 18.5 in, Wire Shielded Cable: 5 kV: 12.75 in
    National Stock Number
    5940005780956
    Number of Conductors
    1
    Number of Skirts
    0
    Poly/EPR Cable Conductor Sizes
    250 kcmil
    Product Type
    Termination Kit
    Suitable for High Voltage
    No
    Tape Type
    Tape Termination Kit
    UV Resistant
    Yes
    Voltage
    15 kV, 25/28 kV, 25/28 kV, 15 kV, 28 kV, 5 kV, 5 kV, 15 kV, 8 kV, 8 kV
    Vulcanizing
    No
    Details
    • Terminates solid dielectric shielded power cables rated 5 to 15 kV
    • Withstands voltages from 5 to 15 kV
    • Comes with sufficient materials to make 3 terminations

    Scotch® Termination Kit 5701 includes sufficient materials to make 3 terminations. This kit is designed to terminate solid dielectric shielded power cables with tape shield, wire shield, UniShield® and concentric neutral construction in weather protected areas.