1. 3M United States
  2. All 3M Products
  • 3M™ Three Conductor Termination Kits Qt-Iii 7600 Series 7686-S-8-3-Rjs
  • 3M™ Three Conductor Termination Kits Qt-Iii 7600 Series 7686-S-8-3-Rjs

    Part Number 7686-S-8-3-RJS3M ID 80611471907UPC 00051128595312
    • Provides a void-free seal to tape shield, wire shield and UniShield® power cables
    • High dielectric-constant material regulates the distribution of electric field stress
    • Suitable for outdoor applications and cabinet-mount installations
    • Termination has 1.53 to 1.81-in insulation O.D.
     More...
    View all details
    Specifications
    Attribute Name
    Value
    Agency Approvals
    IEEE
    Breakout Boot
    No
    Cable Insulation Outside Diameter Range
    1.53-1.81 in
    Cable Insulation Outside Diameter Range (Metric)
    38.8-46.0mm
    Cable Shielding
    Tape Shield, UniShield®, Wire Shield
    Case Quantity
    1
    Conductor Sizes
    1000 kcmil, 350 kcmil, 400 kcmil, 500 kcmil, 600 kcmil, 700 kcmil, 750 kcmil, 800 kcmil, 900 kcmil
    Family
    QT-III
    Indoor/Outdoor
    Outdoor Skirted
    Insulation Level
    100%, 133%
    Insulation Outer Diameter (Imperial)
    1.53 in, 1.55 in, 1.56 in, 1.57 in, 1.58 in, 1.59 in, 1.6 in, 1.61 in, 1.62 in, 1.63 in, 1.64 in, 1.65 in, 1.66 in, 1.67 in, 1.68 in, 1.69 in, 1.7 in, 1.71 in, 1.72 in, 1.73 in, 1.74 in, 1.75 in, 1.76 in, 1.77 in, 1.78 in, 1.79 in, 1.8 in, 1.81 in
    Insulation Rejacketing
    Yes
    Lug/Stem Connector Included in Kit
    No
    Maximum Installed Length
    Termination only (not including RJS sleeving or Break-out boot: 21.5")
    Maximum Installed Length (Metric)
    Termination only (not including RJS sleeving or Break-out boot: 546mm)
    Number of Conductors
    3
    Number of Skirts
    8
    Voltage
    15 kV, 25 kV, 35 kV
    Details
    • Provides a void-free seal to tape shield, wire shield and UniShield® power cables
    • High dielectric-constant material regulates the distribution of electric field stress
    • Suitable for outdoor applications and cabinet-mount installations
    • Termination has 1.53 to 1.81-in insulation O.D.
    • Accommodates wire sizes of 500 to 750 kcmil at 35kV
    • Integrated design allows for easier installation, while sealing compounds provide constant radial pressure
    • Withstands voltages of 5 to 35kV and is 200 kV BIL-rated
    • Includes an 8-skirt, 3-phase, cold shrink termination
    • JIS,‎ IEC and AEIC Approved

    3M™ Cold Shrink QT-III 7600-S-3RJS Series Termination Kit includes a skirted, 3-phase termination. It ensures a pliable, tight seal for tape shield, wire shield and UniShield® power cables. The conjunction of high dielectric-constant material and sealing compounds allows the termination to withstand voltages of 5 to 35kV.

    3M™ Cold Shrink QT-III 7600-S-3RJS Series Termination Kit is designed for terminating medium voltage, 3-conductor cables with or without internal ground wires. The UV stable, track-resistant construction makes the termination suitable for outdoor applications. The lower surface stress, high dielectric-constant material offers an optimized BIL performance while ensuring a leak-proof, compact fit. ‎ JIS,‎ IEC and AEIC Approved.