  • 3M™ Three Conductor Termination Kits Qt-Iii 7600 Series 7696-T-150-3 g
  • 3M™ Three Conductor Termination Kits Qt-Iii 7600 Series 7696-T-150-3 g

    Part Number 7696-T-150-3G3M ID 80611471915UPC 00051128595329
    • Provides a void-free seal to tape shield, wire shield and UniShield® power cables
    • High dielectric-constant material regulates the distribution of electric field stress
    • Suitable for indoor applications
    • Termination has 1.53 to 1.81-in insulation O.D. and 5.40-in maximum cable O.D.
     More...
    Specifications
    Attribute Name
    Value
    Agency Approvals
    IEEE
    BIL
    150 kV
    Breakout Boot
    Yes
    Cable Insulation Outside Diameter Range
    1.53-1.81 in
    Cable Insulation Outside Diameter Range (Metric)
    38.8-46.0mm
    Cable Shielding
    Tape Shield, UniShield®, Wire Shield
    Case Quantity
    1
    Conductor Size Range
    (15 kV, 133%) 1000 kcmil, (25/28 kV, 100%) 750 kcmil, (25/28 kV, 133%) 500-750 kcmil, (35 kV, 100%) 500-750 kcmil, (35 kV, 133%) 350-750 kcmil
    Conductor Sizes
    1000 kcmil, 350 kcmil, 400 kcmil, 500 kcmil, 600 kcmil, 700 kcmil, 750 kcmil, 800 kcmil, 900 kcmil
    Family
    QT-III
    Indoor/Outdoor
    Indoor Non-skirted
    Insulation Level
    100%, 133%
    Insulation Outer Diameter (Imperial)
    1.53 in, 1.55 in, 1.56 in, 1.57 in, 1.58 in, 1.59 in, 1.6 in, 1.61 in, 1.62 in, 1.63 in, 1.64 in, 1.65 in, 1.66 in, 1.67 in, 1.68 in, 1.69 in, 1.7 in, 1.71 in, 1.72 in, 1.73 in, 1.74 in, 1.75 in, 1.76 in, 1.77 in, 1.78 in, 1.79 in, 1.8 in, 1.81 in
    Insulation Rejacketing
    Yes
    Lug/Stem Connector Included in Kit
    No
    Maximum Cable Outside Diameter
    5.40 in
    Maximum Cable Outside Diameter (Metric)
    137.2 mm
    Maximum Installed Length
    16.00 in
    Maximum Installed Length (Metric)
    Termination only (not including RJS sleeving or Break-out boot: 546mm)
    Number of Conductors
    3
    Number of Skirts
    8
    Product Series
    3-RJS
    RoHS 2011/65/EU Compliant
    Undetermined
    RoHS EU Comments
    Contact 3M for information
    *Important RoHS information
    TDS Required
    Yes
    Voltage
    15 kV, 25/28 kV, 35 kV
    Details
    • Provides a void-free seal to tape shield, wire shield and UniShield® power cables
    • High dielectric-constant material regulates the distribution of electric field stress
    • Suitable for indoor applications
    • Termination has 1.53 to 1.81-in insulation O.D. and 5.40-in maximum cable O.D.
    • Accommodates wire sizes 1000 kcmil at 15kV 133%, 750 kcmil at 25/28 kV 100%, 500 to 750 kcmil at 25/28 kV 133%, 500 to 750 kcmil at 35kV 100%, 350 to 750 kcmil at 35kV 133%
    • Silicone rubber insulation offers durability and reduces leakage currents in damp conditions
    • Withstands voltages of 5 to 35kV and is 150 kV BIL-rated
    • Includes a non-skirted, 3-phase, cold shrink termination
    • IEEE Approved

    3M™ Cold Shrink QT-III 7600-T-3G Series Termination Kit includes a non-skirted, 3-phase termination. It ensures a pliable, tight seal for tape shield, wire shield and UniShield® power cables. The silicone rubber sealing compounds allow the termination to withstand voltages of 5 to 35kV.

    3M™ Cold Shrink QT-III 7600-T-3G Series Termination Kit is designed for terminating medium voltage, 3/C-shielded, 3-conductor cables with internal ground wires. The UV stable, track-resistant and hydrophobic construction makes the termination suitable for indoor applications. The lower surface stress, high dielectric-constant material offers an optimized BIL performance while ensuring a leak-proof, compact fit. IEEE Approved.