1. 3M United States
  2. All 3M Products
  • 3M™ Rejacketing Sleeves RJS Series
  • 3M™ Rejacketing Sleeves RJS Series

    10  Products
    • Offers good resistance to moisture, corrosion, ozone and UV rays
    • Secures the phase legs of medium-voltage and 3/C shielded power cables
    • Designed for use on tape shield, wire shield, armored and non-armored power cables
    • Comes in dark gray color
     More...
    View all details
    Overall Length (Imperial)
    Overall_Length_Imperial
    10 Products Available
    Available options:
     Overall Length (Imperial)
    All Options
    Close
    Specifications
    Attribute Name
    Value
    Brand
    3M™
    Breakout Boot
    No
    Cable Accessory Products
    Cable Breakout Boot Kits
    Cable Insulation Outside Diameter Range
    0.43 - 0.60 in, 1.02 - 1.28 in
    Color Family
    Gray
    Conductor Size by Voltage
    (10 kV, IEC) 185–300 mm², (10 kV, IEC) 70–150 mm², (15 kV, AEIC) 1/0–4/0 AWG, (15 kV, AEIC) 250–450 kcmil, (15 kV, AEIC) 500–750 kcmil, (20 kV, IEC) 240–300 mm², (20 kV, IEC) 25–70 mm², (20 kV, IEC) 95–185 mm², (25 kV, AEIC) 2/0 AWG–250 kcmil, (25 kV, AEIC) 2–1/0 AWG, (25 kV, AEIC) 300–500 kcmil, (3.3 kV, IEC) 120–185 mm², (3.3 kV, IEC) 16–35 mm², (3.3 kV, JIS) 8–22 mm², (5.0 kV, AEIC) 8–2 AWG, (6.6 kV, JIS) 16–25 mm², (6.6 kV, IEC) 8–10 mm², (8.0 kV, AEIC) 6–4 AWG,, (3.3 kV, IEC) 240–300 mm², (3.3 kV, IEC) 50–95 mm², (3.3 kV, JIS) 38–60 mm², (5.0 kV, AEIC) 1–3/0 AWG, (6.6 kV, JIS) 35–70 mm², (6.6 kV, IEC) 14–38 mm², (8.0 kV, AEIC) 2–2/0 AWG, (10 kV, IEC) 10–50 mm², (15 kV, AEIC) 2–1 AWG,, (3.3 kV, JIS) 100–150 mm², (3.3 kV, JIS) 200–250 mm², (3.3 kV, JIS) 300–325 mm², (30 kV, IEC) 35–70 mm², (30 kV, IEC) 95–240 mm², (35 kV, AEIC) 1/0–3/0 AWG, (35 kV, AEIC) 4/0 AWG–500 kcmil, (5.0 kV, AEIC) 4/0 AWG–400 kcmil, (5.0 kV, AEIC) 500–750 kcmil, (5.0 kV, AEIC) 800–1000 kcmil, (6.6 kV, IEC) 150–250 mm², (6.6 kV, IEC) 300–325 mm², (6.6 kV, IEC) 60–100 mm², (6.6 kV, JIS) 185–300 mm², (6.6 kV, JIS) 95–150 mm², (8.0 kV, AEIC) 3/0 AWG–350 kcmil, (8.0 kV, AEIC) 400–600 kcmil, (8.0 kV, AEIC) 750–1000 kcmil
    Dielectric Strength (V/mil)
    428 V/mil
    Elongation
    910 %
    Inner Diameter After Shrink (Imperial)
    0.4 in, 0.6 in, 0.8 in, 1 in, 1.3 in
    Inner Diameter After Shrink (Metric)
    10.9 mm, 15.2 mm, 20.3 mm, 25.9 mm, 32.5 mm
    Inner Diameter Before Shrink (Imperial)
    0.6 in, 0.8 in, 1.02 in, 1.28 in, 1.62 in
    Inner Diameter Before Shrink (Metric)
    15.2 mm, 20.3 mm, 25.9 mm, 32.5 mm, 41.1 mm
    Insulation Rejacketing
    Yes
    Manufacturing Origin
    USA
    Metallic Shield Diameter Range
    0.43 - 0.60 in, 0.60 - 0.80 in, 0.80 - 1.02 in, 1.02 - 1.28 in, 1.28 - 1.62 in
    Metallic Shield Diameter Range (Metric)
    10.9-15.2 mm, 15.2-20.3 mm, 20.3-25.9 mm, 25.9-32.5 mm, 32.5-41.1 mm
    Operating Temperature (Celsius)
    105
    Operating Temperature (Fahrenheit)
    194, 221 Degree Fahrenheit
    Overall Length (Imperial)
    10 ft, 4 ft
    Overall Length (Metric)
    1219 mm, 3048 mm
    Product Color
    Dark Gray
    Product Type
    Splice Jacketing and Rejacketing Kits
    Solution
    utilitybreakout
    Temperature Rating
    356°F (180°C) Class H
    Tensile Strength (Imperial)
    1058 Pound-Force Per Square Inch
    Units per Case
    1, 10
    Voltage Range
    3.3 - 15 kV, 3.3 - 25 kV, 3.3 - 35 kV, 3.3 - 8 kV
    Details
    • Offers good resistance to moisture, corrosion, ozone and UV rays
    • Secures the phase legs of medium-voltage and 3/C shielded power cables
    • Designed for use on tape shield, wire shield, armored and non-armored power cables
    • Comes in dark gray color
    • Silicone rubber insulator on inner-expandable polyester braid minimizes sliding friction and ensures a leak-proof seal
    • Voltages of up to 35 kV or less

    3M™ Rejacketing Sleeve provides reliable safety and protection to the phase legs of 3/C shielded, medium voltage power cables from termination operating environments. Incorporated with a silicone rubber insulator and polyester braid, this sleeve is resistant to UV rays, ozone, corrosion and moisture. It is designed for use with 3M Cold Shrink QT II and QT III, Silicone Rubber Terminations.

    3M™ Rejacketing Sleeve works in combination with cold shrink breakout boots and silicone rubber terminations. It is ideal for tape shield, wire shield, armored and non armored power cables. The rejacketing sleeves are designed to protect the phase legs from exosure to: moisture, corrosion, ozone, ultra violet radiation and other hazards associated with termination operating environments. Easy to adjust length, the sleeve conforms to varied equipment connections and mounting requirements.