1. All 3M Products
  • 3M™ Ranger™ High Flow Disposable Set, Model 24355, 10/Case
  • 3M™ Ranger™ High Flow Disposable Set, Model 24355, 10/Case

    Catalog Number 243553M ID 70200793258UPC 50707387781441
    • Rated from 150 mL/hr to 30,000 mL/hr at 300 mmHg
    • Low resistant path engineered for optimum performance
    • Safely warms fluids up to 30,000 mL/hr
    • Dry heat technology responds to a wide range of flow rates
     More...
    Specifications
    Attribute Name
    Value
    Approved Environmental Marketing Claim (EMC)
    Not made with DEHP
    Brand
    Ranger™
    Clinical Area
    ER, OR
    Contents
    Heat exchanger, auto-venting bubble trap, needleless IV injection port, 2 IV spikes, drip chamber with 150 micron filter, 60 inch patient line|| Heat exchanger, auto-venting bubble trap, needleless IV injection port, 2 IV spikes, drip chamber with 150 micron filter, 60 inch patient line
    Environmental claim being made
    Yes
    Environmental claim relates to
    Product
    Fluid Type
    Blood/Fluid
    Model
    24355
    Pressure Infusion
    Up to 300 mmHg maximum dynamic operating pressure
    Priming Volume
    150 mL
    Product Type
    Disposable Set
    Quantity
    10 Case
    Set Type
    High Flow
    Sterile
    EtO
    TDS Required
    No
    Units per Pack
    10
    Product Details
    • Rated from 150 mL/hr to 30,000 mL/hr at 300 mmHg
    • Low resistant path engineered for optimum performance
    • Safely warms fluids up to 30,000 mL/hr
    • Dry heat technology responds to a wide range of flow rates
    • Keeps fluids warm in trauma situations
    • Needleless IV injection port
    • Drip rate of 20 drips per mL
    • Replaceable 150 micron filter
    • Latex-free

    When rapidly infusing blood or IV fluids it is important to have a disposable set that is up to the task. This set includes an auto venting bubble trap that is able to vent up to 3,000 mL of air per minute. With a priming volume of 150 mL, the Model 24355

    Designed to handle flow rates from KVO to 30,000 mL/hr, the high flow set is used for those cases where large volume infusion is anticipated. This set can be used as a gravity flow system or with maximum dynamic operating pressure infusion up to 300 mmHg. When rapidly infusing fluid, it is important to guard against air embolism. The system is equipped with an auto-venting bubble trap capable of venting up to 3,000 mL of air per minute.

    Suggested Applications

    • OR, Trauma
    Product Support

    Specific product and application questions

    Product Support1-800-228-3957
    Follow Us
    The brands listed above are trademarks of 3M.
    Change Location
    United States - English