1. All 3M Products

3M™ RJS Series Rejacketing Sleeves

10  Products
Cable Insulation Outside Diameter Range
Conductor Size by Voltage
10 Products Available
Available options:
 Cable Insulation Outside Diameter Range and Conductor Size by Voltage
All Options
  • Conductor Size by Voltage
    Cable Insulation Outside Diameter Range
  • (10 kV, IEC) 70–150 mm², (15 kV, AEIC) 1/0–4/0 AWG, (20 kV, IEC) 25–70 mm², (25 kV, AEIC) 2–1/0 AWG, (3.3 kV, IEC) 120–185 mm², (3.3 kV, JIS) 100–150 mm², (5.0 kV, AEIC) 4/0 AWG–400 kcmil, (6.6 kV, IEC) 60–100 mm², (6.6 kV, JIS) 95–150 mm², (8.0 kV, AEIC) 3/0 AWG–350 kcmil
  • (10 kV, IEC) 70–150 mm², (15 kV, AEIC) 1/0–4/0 AWG, (20 kV, IEC) 25–70 mm², (25 kV, AEIC) 2–1/0 AWG, (3.3 kV, IEC) 120–185 mm², (3.3 kV, JIS) 100–150 mm², (5.0 kV, AEIC) 4/0 AWG–400 kcmil, (6.6 kV, IEC) 60–100 mm², (6.6 kV, JIS) 95–150 mm², (8.0 kV, AEIC) 3/0 AWG–350 kcmil
  • (15 kV, AEIC) 500–750 kcmil, (20 kV, IEC) 240–300 mm², (25 kV, AEIC) 300–500 kcmil, (3.3 kV, JIS) 300–325 mm², (30 kV, IEC) 95–240 mm², (35 kV, AEIC) 4/0 AWG–500 kcmil, (5.0 kV, AEIC) 800–1000 kcmil, (6.6 kV, IEC) 300–325 mm², (8.0 kV, AEIC) 750–1000 kcmil
  • 1.02 - 1.28 in
    (10 kV, IEC) 185–300 mm², (15 kV, AEIC) 250–450 kcmil, (20 kV, IEC) 95–185 mm², (25 kV, AEIC) 2/0 AWG–250 kcmil, (3.3 kV, IEC) 240–300 mm², (3.3 kV, JIS) 200–250 mm², (30 kV, IEC) 35–70 mm², (35 kV, AEIC) 1/0–3/0 AWG, (5.0 kV, AEIC) 500–750 kcmil, (6.6 kV, IEC) 150–250 mm², (6.6 kV, JIS) 185–300 mm², (8.0 kV, AEIC) 400–600 kcmil
  • (15 kV, AEIC) 500–750 kcmil, (20 kV, IEC) 240–300 mm², (25 kV, AEIC) 300–500 kcmil, (3.3 kV, JIS) 300–325 mm², (30 kV, IEC) 95–240 mm², (35 kV, AEIC) 4/0 AWG–500 kcmil, (5.0 kV, AEIC) 800–1000 kcmil, (6.6 kV, IEC) 300–325 mm², (8.0 kV, AEIC) 750–1000 kcmil
  • (3.3 kV, IEC) 50–95 mm², (3.3 kV, JIS) 38–60 mm², (5.0 kV, AEIC) 1–3/0 AWG, (6.6 kV, JIS) 35–70 mm², (6.6 kV, IEC) 14–38 mm², (8.0 kV, AEIC) 2–2/0 AWG, (10 kV, IEC) 10–50 mm², (15 kV, AEIC) 2–1 AWG,
  • (10 kV, IEC) 185–300 mm², (15 kV, AEIC) 250–450 kcmil, (20 kV, IEC) 95–185 mm², (25 kV, AEIC) 2/0 AWG–250 kcmil, (3.3 kV, IEC) 240–300 mm², (3.3 kV, JIS) 200–250 mm², (30 kV, IEC) 35–70 mm², (35 kV, AEIC) 1/0–3/0 AWG, (5.0 kV, AEIC) 500–750 kcmil, (6.6 kV, IEC) 150–250 mm², (6.6 kV, JIS) 185–300 mm², (8.0 kV, AEIC) 400–600 kcmil
  • (3.3 kV, IEC) 50–95 mm², (3.3 kV, JIS) 38–60 mm², (5.0 kV, AEIC) 1–3/0 AWG, (6.6 kV, JIS) 35–70 mm², (6.6 kV, IEC) 14–38 mm², (8.0 kV, AEIC) 2–2/0 AWG, (10 kV, IEC) 10–50 mm², (15 kV, AEIC) 2–1 AWG,
  • (3.3 kV, IEC) 16–35 mm², (3.3 kV, JIS) 8–22 mm², (5.0 kV, AEIC) 8–2 AWG, (6.6 kV, JIS) 16–25 mm², (6.6 kV, IEC) 8–10 mm², (8.0 kV, AEIC) 6–4 AWG,
  • 0.43 - 0.60 in
    (3.3 kV, IEC) 16–35 mm², (3.3 kV, JIS) 8–22 mm², (5.0 kV, AEIC) 8–2 AWG, (6.6 kV, JIS) 16–25 mm², (6.6 kV, IEC) 8–10 mm², (8.0 kV, AEIC) 6–4 AWG,
Close
Specifications
Attribute Name
Value
Brand
3M™
Breakout Boot
No
Cable Accessory Products
Cable Breakout Boot Kits
Cable Insulation Outside Diameter Range
0.43 - 0.60 in, 1.02 - 1.28 in
Color
Gray, Dark Gray
Conductor Size by Voltage
(10 kV, IEC) 185–300 mm², (10 kV, IEC) 70–150 mm², (15 kV, AEIC) 1/0–4/0 AWG, (15 kV, AEIC) 250–450 kcmil, (15 kV, AEIC) 500–750 kcmil, (20 kV, IEC) 240–300 mm², (20 kV, IEC) 25–70 mm², (20 kV, IEC) 95–185 mm², (25 kV, AEIC) 2/0 AWG–250 kcmil, (25 kV, AEIC) 2–1/0 AWG, (25 kV, AEIC) 300–500 kcmil, (3.3 kV, IEC) 120–185 mm², (3.3 kV, IEC) 16–35 mm², (3.3 kV, JIS) 8–22 mm², (5.0 kV, AEIC) 8–2 AWG, (6.6 kV, JIS) 16–25 mm², (6.6 kV, IEC) 8–10 mm², (8.0 kV, AEIC) 6–4 AWG,, (3.3 kV, IEC) 240–300 mm², (3.3 kV, IEC) 50–95 mm², (3.3 kV, JIS) 38–60 mm², (5.0 kV, AEIC) 1–3/0 AWG, (6.6 kV, JIS) 35–70 mm², (6.6 kV, IEC) 14–38 mm², (8.0 kV, AEIC) 2–2/0 AWG, (10 kV, IEC) 10–50 mm², (15 kV, AEIC) 2–1 AWG,, (3.3 kV, JIS) 100–150 mm², (3.3 kV, JIS) 200–250 mm², (3.3 kV, JIS) 300–325 mm², (30 kV, IEC) 35–70 mm², (30 kV, IEC) 95–240 mm², (35 kV, AEIC) 1/0–3/0 AWG, (35 kV, AEIC) 4/0 AWG–500 kcmil, (5.0 kV, AEIC) 4/0 AWG–400 kcmil, (5.0 kV, AEIC) 500–750 kcmil, (5.0 kV, AEIC) 800–1000 kcmil, (6.6 kV, IEC) 150–250 mm², (6.6 kV, IEC) 300–325 mm², (6.6 kV, IEC) 60–100 mm², (6.6 kV, JIS) 185–300 mm², (6.6 kV, JIS) 95–150 mm², (8.0 kV, AEIC) 3/0 AWG–350 kcmil, (8.0 kV, AEIC) 400–600 kcmil, (8.0 kV, AEIC) 750–1000 kcmil
Dielectric Strength (V/mil)
428 V/mil
Elongation
910 %
Inner Diameter Before Shrink (Imperial)
0.6 in, 0.8 in, 1.02 in, 1.28 in, 1.62 in
Insulation Rejacketing
Yes
Length
10 Linear Foot, 4 Linear Foot
Length (Metric)
121.92, 304.8 m
Metallic Shield Diameter Range
0.43 - 0.60 in, 0.60 - 0.80 in, 0.80 - 1.02 in, 1.02 - 1.28 in, 1.28 - 1.62 in
Metallic Shield Diameter Range (Metric)
10.9-15.2 mm, 15.2-20.3 mm, 20.3-25.9 mm, 25.9-32.5 mm, 32.5-41.1 mm
Operating Temperature (Celsius)
105
Operating Temperature (Fahrenheit)
194, 221 Degree Fahrenheit
Product Type
Splice Jacketing and Rejacketing Kits
RoHS 2011/65/EU Compliant
Undetermined
RoHS EU Comments
Contact 3M for information
*Important RoHS information
Temperature Rating
356°F (180°C) Class H
Tensile Strength (Imperial)
1058 Pound-Force Per Square Inch
Voltage Range
3.3 - 15 kV, 3.3 - 25 kV, 3.3 - 35 kV, 3.3 - 8 kV
Details

3M™ Silicone Rubber RJS Series 3/C Phase Rejacketing Systems are designed to be used in conjunction with 3M™ Terminations to seal the breakout area and rejacket the phases on three conductor cable without grounds.