1. All 3M Products

3M™ RJS Series Rejacketing Sleeves

10  Products
     More...
    View Legal Disclaimer
    Cable Insulation Outside Diameter Range
    Cable_Insulation_Outside_Diameter_Range
    Conductor Size by Voltage
    Conductor_Size_by_Voltage
    10 Products Available
    Available options:
     Cable Insulation Outside Diameter Range and Conductor Size by Voltage
    All Options
    • Conductor Size by Voltage
      Cable Insulation Outside Diameter Range
    • (10 kV, IEC) 70–150 mm², (15 kV, AEIC) 1/0–4/0 AWG, (20 kV, IEC) 25–70 mm², (25 kV, AEIC) 2–1/0 AWG, (3.3 kV, IEC) 120–185 mm², (3.3 kV, JIS) 100–150 mm², (5.0 kV, AEIC) 4/0 AWG–400 kcmil, (6.6 kV, IEC) 60–100 mm², (6.6 kV, JIS) 95–150 mm², (8.0 kV, AEIC) 3/0 AWG–350 kcmil
    • (10 kV, IEC) 70–150 mm², (15 kV, AEIC) 1/0–4/0 AWG, (20 kV, IEC) 25–70 mm², (25 kV, AEIC) 2–1/0 AWG, (3.3 kV, IEC) 120–185 mm², (3.3 kV, JIS) 100–150 mm², (5.0 kV, AEIC) 4/0 AWG–400 kcmil, (6.6 kV, IEC) 60–100 mm², (6.6 kV, JIS) 95–150 mm², (8.0 kV, AEIC) 3/0 AWG–350 kcmil
    • (15 kV, AEIC) 500–750 kcmil, (20 kV, IEC) 240–300 mm², (25 kV, AEIC) 300–500 kcmil, (3.3 kV, JIS) 300–325 mm², (30 kV, IEC) 95–240 mm², (35 kV, AEIC) 4/0 AWG–500 kcmil, (5.0 kV, AEIC) 800–1000 kcmil, (6.6 kV, IEC) 300–325 mm², (8.0 kV, AEIC) 750–1000 kcmil
    • 1.02 - 1.28 in
      (10 kV, IEC) 185–300 mm², (15 kV, AEIC) 250–450 kcmil, (20 kV, IEC) 95–185 mm², (25 kV, AEIC) 2/0 AWG–250 kcmil, (3.3 kV, IEC) 240–300 mm², (3.3 kV, JIS) 200–250 mm², (30 kV, IEC) 35–70 mm², (35 kV, AEIC) 1/0–3/0 AWG, (5.0 kV, AEIC) 500–750 kcmil, (6.6 kV, IEC) 150–250 mm², (6.6 kV, JIS) 185–300 mm², (8.0 kV, AEIC) 400–600 kcmil
    • (15 kV, AEIC) 500–750 kcmil, (20 kV, IEC) 240–300 mm², (25 kV, AEIC) 300–500 kcmil, (3.3 kV, JIS) 300–325 mm², (30 kV, IEC) 95–240 mm², (35 kV, AEIC) 4/0 AWG–500 kcmil, (5.0 kV, AEIC) 800–1000 kcmil, (6.6 kV, IEC) 300–325 mm², (8.0 kV, AEIC) 750–1000 kcmil
    • (3.3 kV, IEC) 50–95 mm², (3.3 kV, JIS) 38–60 mm², (5.0 kV, AEIC) 1–3/0 AWG, (6.6 kV, JIS) 35–70 mm², (6.6 kV, IEC) 14–38 mm², (8.0 kV, AEIC) 2–2/0 AWG, (10 kV, IEC) 10–50 mm², (15 kV, AEIC) 2–1 AWG,
    • (10 kV, IEC) 185–300 mm², (15 kV, AEIC) 250–450 kcmil, (20 kV, IEC) 95–185 mm², (25 kV, AEIC) 2/0 AWG–250 kcmil, (3.3 kV, IEC) 240–300 mm², (3.3 kV, JIS) 200–250 mm², (30 kV, IEC) 35–70 mm², (35 kV, AEIC) 1/0–3/0 AWG, (5.0 kV, AEIC) 500–750 kcmil, (6.6 kV, IEC) 150–250 mm², (6.6 kV, JIS) 185–300 mm², (8.0 kV, AEIC) 400–600 kcmil
    • (3.3 kV, IEC) 50–95 mm², (3.3 kV, JIS) 38–60 mm², (5.0 kV, AEIC) 1–3/0 AWG, (6.6 kV, JIS) 35–70 mm², (6.6 kV, IEC) 14–38 mm², (8.0 kV, AEIC) 2–2/0 AWG, (10 kV, IEC) 10–50 mm², (15 kV, AEIC) 2–1 AWG,
    • (3.3 kV, IEC) 16–35 mm², (3.3 kV, JIS) 8–22 mm², (5.0 kV, AEIC) 8–2 AWG, (6.6 kV, JIS) 16–25 mm², (6.6 kV, IEC) 8–10 mm², (8.0 kV, AEIC) 6–4 AWG,
    • 0.43 - 0.60 in
      (3.3 kV, IEC) 16–35 mm², (3.3 kV, JIS) 8–22 mm², (5.0 kV, AEIC) 8–2 AWG, (6.6 kV, JIS) 16–25 mm², (6.6 kV, IEC) 8–10 mm², (8.0 kV, AEIC) 6–4 AWG,
    Close
    Specifications
    Attribute Name
    Value
    Brand
    3M™
    Breakout Boot
    No
    Cable Accessory Products
    Cable Breakout Boot Kits
    Cable Insulation Outside Diameter Range
    0.43 - 0.60 in, 1.02 - 1.28 in
    Color Family
    Gray
    Conductor Size by Voltage
    (10 kV, IEC) 185–300 mm², (10 kV, IEC) 70–150 mm², (15 kV, AEIC) 1/0–4/0 AWG, (15 kV, AEIC) 250–450 kcmil, (15 kV, AEIC) 500–750 kcmil, (20 kV, IEC) 240–300 mm², (20 kV, IEC) 25–70 mm², (20 kV, IEC) 95–185 mm², (25 kV, AEIC) 2/0 AWG–250 kcmil, (25 kV, AEIC) 2–1/0 AWG, (25 kV, AEIC) 300–500 kcmil, (3.3 kV, IEC) 120–185 mm², (3.3 kV, IEC) 16–35 mm², (3.3 kV, JIS) 8–22 mm², (5.0 kV, AEIC) 8–2 AWG, (6.6 kV, JIS) 16–25 mm², (6.6 kV, IEC) 8–10 mm², (8.0 kV, AEIC) 6–4 AWG,, (3.3 kV, IEC) 240–300 mm², (3.3 kV, IEC) 50–95 mm², (3.3 kV, JIS) 38–60 mm², (5.0 kV, AEIC) 1–3/0 AWG, (6.6 kV, JIS) 35–70 mm², (6.6 kV, IEC) 14–38 mm², (8.0 kV, AEIC) 2–2/0 AWG, (10 kV, IEC) 10–50 mm², (15 kV, AEIC) 2–1 AWG,, (3.3 kV, JIS) 100–150 mm², (3.3 kV, JIS) 200–250 mm², (3.3 kV, JIS) 300–325 mm², (30 kV, IEC) 35–70 mm², (30 kV, IEC) 95–240 mm², (35 kV, AEIC) 1/0–3/0 AWG, (35 kV, AEIC) 4/0 AWG–500 kcmil, (5.0 kV, AEIC) 4/0 AWG–400 kcmil, (5.0 kV, AEIC) 500–750 kcmil, (5.0 kV, AEIC) 800–1000 kcmil, (6.6 kV, IEC) 150–250 mm², (6.6 kV, IEC) 300–325 mm², (6.6 kV, IEC) 60–100 mm², (6.6 kV, JIS) 185–300 mm², (6.6 kV, JIS) 95–150 mm², (8.0 kV, AEIC) 3/0 AWG–350 kcmil, (8.0 kV, AEIC) 400–600 kcmil, (8.0 kV, AEIC) 750–1000 kcmil
    Dielectric Strength (V/mil)
    428 V/mil
    Elongation
    910 %
    Inner Diameter After Shrink (Imperial)
    0.4 in, 0.6 in, 0.8 in, 1 in, 1.3 in
    Inner Diameter After Shrink (Metric)
    10.9 mm, 15.2 mm, 20.3 mm, 25.9 mm, 32.5 mm
    Inner Diameter Before Shrink (Imperial)
    0.6 in, 0.8 in, 1.02 in, 1.28 in, 1.62 in
    Inner Diameter Before Shrink (Metric)
    15.2 mm, 20.3 mm, 25.9 mm, 32.5 mm, 41.1 mm
    Insulation Rejacketing
    Yes
    Manufacturing Origin
    USA
    Metallic Shield Diameter Range
    0.43 - 0.60 in, 0.60 - 0.80 in, 0.80 - 1.02 in, 1.02 - 1.28 in, 1.28 - 1.62 in
    Metallic Shield Diameter Range (Metric)
    10.9-15.2 mm, 15.2-20.3 mm, 20.3-25.9 mm, 25.9-32.5 mm, 32.5-41.1 mm
    Operating Temperature (Celsius)
    105
    Operating Temperature (Fahrenheit)
    194, 221 Degree Fahrenheit
    Overall Length (Imperial)
    10 ft, 4 ft
    Overall Length (Metric)
    1219 mm, 3048 mm
    Product Color
    Dark Gray
    Product Type
    Splice Jacketing and Rejacketing Kits
    Solution
    utilitybreakout
    Temperature Rating
    356°F (180°C) Class H
    Tensile Strength (Imperial)
    1058 Pound-Force Per Square Inch
    Voltage Range
    3.3 - 15 kV, 3.3 - 25 kV, 3.3 - 35 kV, 3.3 - 8 kV
    Details

    3M™ Silicone Rubber RJS Series 3/C Phase Rejacketing Systems are designed to be used in conjunction with 3M™ Terminations to seal the breakout area and rejacket the phases on three conductor cable without grounds.

    Legal Disclaimer

    Manufacturing Origin: USA

    The designation that a product is Manufactured in the USA means the product undergoes substantial transformation in one of our U.S. Manufacturing plants. Some products contain imported components.

    Note: 3M products offered on a government contract that require country of origin representation must be certified by 3M Trade Compliance. Contact customer service at 800-245-3573 to request a certificate.