    10  Products
    Cable Insulation Outside Diameter Range
    Cable_Insulation_Outside_Diameter_Range
    Conductor Size by Voltage
    Conductor_Size_by_Voltage
    10 Products Available
    Available options:
     Cable Insulation Outside Diameter Range and Conductor Size by Voltage
    All Options
    • Conductor Size by Voltage
      Cable Insulation Outside Diameter Range
    • (10 kV, IEC) 70–150 mm², (15 kV, AEIC) 1/0–4/0 AWG, (20 kV, IEC) 25–70 mm², (25 kV, AEIC) 2–1/0 AWG, (3.3 kV, IEC) 120–185 mm², (3.3 kV, JIS) 100–150 mm², (5.0 kV, AEIC) 4/0 AWG–400 kcmil, (6.6 kV, IEC) 60–100 mm², (6.6 kV, JIS) 95–150 mm², (8.0 kV, AEIC) 3/0 AWG–350 kcmil
    • (10 kV, IEC) 70–150 mm², (15 kV, AEIC) 1/0–4/0 AWG, (20 kV, IEC) 25–70 mm², (25 kV, AEIC) 2–1/0 AWG, (3.3 kV, IEC) 120–185 mm², (3.3 kV, JIS) 100–150 mm², (5.0 kV, AEIC) 4/0 AWG–400 kcmil, (6.6 kV, IEC) 60–100 mm², (6.6 kV, JIS) 95–150 mm², (8.0 kV, AEIC) 3/0 AWG–350 kcmil
    • (15 kV, AEIC) 500–750 kcmil, (20 kV, IEC) 240–300 mm², (25 kV, AEIC) 300–500 kcmil, (3.3 kV, JIS) 300–325 mm², (30 kV, IEC) 95–240 mm², (35 kV, AEIC) 4/0 AWG–500 kcmil, (5.0 kV, AEIC) 800–1000 kcmil, (6.6 kV, IEC) 300–325 mm², (8.0 kV, AEIC) 750–1000 kcmil
    • 1.02 - 1.28 in
      (10 kV, IEC) 185–300 mm², (15 kV, AEIC) 250–450 kcmil, (20 kV, IEC) 95–185 mm², (25 kV, AEIC) 2/0 AWG–250 kcmil, (3.3 kV, IEC) 240–300 mm², (3.3 kV, JIS) 200–250 mm², (30 kV, IEC) 35–70 mm², (35 kV, AEIC) 1/0–3/0 AWG, (5.0 kV, AEIC) 500–750 kcmil, (6.6 kV, IEC) 150–250 mm², (6.6 kV, JIS) 185–300 mm², (8.0 kV, AEIC) 400–600 kcmil
    • (15 kV, AEIC) 500–750 kcmil, (20 kV, IEC) 240–300 mm², (25 kV, AEIC) 300–500 kcmil, (3.3 kV, JIS) 300–325 mm², (30 kV, IEC) 95–240 mm², (35 kV, AEIC) 4/0 AWG–500 kcmil, (5.0 kV, AEIC) 800–1000 kcmil, (6.6 kV, IEC) 300–325 mm², (8.0 kV, AEIC) 750–1000 kcmil
    • (3.3 kV, IEC) 50–95 mm², (3.3 kV, JIS) 38–60 mm², (5.0 kV, AEIC) 1–3/0 AWG, (6.6 kV, JIS) 35–70 mm², (6.6 kV, IEC) 14–38 mm², (8.0 kV, AEIC) 2–2/0 AWG, (10 kV, IEC) 10–50 mm², (15 kV, AEIC) 2–1 AWG,
    • (10 kV, IEC) 185–300 mm², (15 kV, AEIC) 250–450 kcmil, (20 kV, IEC) 95–185 mm², (25 kV, AEIC) 2/0 AWG–250 kcmil, (3.3 kV, IEC) 240–300 mm², (3.3 kV, JIS) 200–250 mm², (30 kV, IEC) 35–70 mm², (35 kV, AEIC) 1/0–3/0 AWG, (5.0 kV, AEIC) 500–750 kcmil, (6.6 kV, IEC) 150–250 mm², (6.6 kV, JIS) 185–300 mm², (8.0 kV, AEIC) 400–600 kcmil
    • (3.3 kV, IEC) 50–95 mm², (3.3 kV, JIS) 38–60 mm², (5.0 kV, AEIC) 1–3/0 AWG, (6.6 kV, JIS) 35–70 mm², (6.6 kV, IEC) 14–38 mm², (8.0 kV, AEIC) 2–2/0 AWG, (10 kV, IEC) 10–50 mm², (15 kV, AEIC) 2–1 AWG,
    • (3.3 kV, IEC) 16–35 mm², (3.3 kV, JIS) 8–22 mm², (5.0 kV, AEIC) 8–2 AWG, (6.6 kV, JIS) 16–25 mm², (6.6 kV, IEC) 8–10 mm², (8.0 kV, AEIC) 6–4 AWG,
    • 0.43 - 0.60 in
      (3.3 kV, IEC) 16–35 mm², (3.3 kV, JIS) 8–22 mm², (5.0 kV, AEIC) 8–2 AWG, (6.6 kV, JIS) 16–25 mm², (6.6 kV, IEC) 8–10 mm², (8.0 kV, AEIC) 6–4 AWG,
    Close
    Specifications
    Attribute Name
    Value
    Brand
    3M™
    Breakout Boot
    No
    Cable Accessory Products
    Cable Breakout Boot Kits
    Cable Insulation Outside Diameter Range
    0.43 - 0.60 in, 1.02 - 1.28 in
    Color
    Gray, Dark Gray
    Conductor Size by Voltage
    (10 kV, IEC) 185–300 mm², (10 kV, IEC) 70–150 mm², (15 kV, AEIC) 1/0–4/0 AWG, (15 kV, AEIC) 250–450 kcmil, (15 kV, AEIC) 500–750 kcmil, (20 kV, IEC) 240–300 mm², (20 kV, IEC) 25–70 mm², (20 kV, IEC) 95–185 mm², (25 kV, AEIC) 2/0 AWG–250 kcmil, (25 kV, AEIC) 2–1/0 AWG, (25 kV, AEIC) 300–500 kcmil, (3.3 kV, IEC) 120–185 mm², (3.3 kV, IEC) 16–35 mm², (3.3 kV, JIS) 8–22 mm², (5.0 kV, AEIC) 8–2 AWG, (6.6 kV, JIS) 16–25 mm², (6.6 kV, IEC) 8–10 mm², (8.0 kV, AEIC) 6–4 AWG,, (3.3 kV, IEC) 240–300 mm², (3.3 kV, IEC) 50–95 mm², (3.3 kV, JIS) 38–60 mm², (5.0 kV, AEIC) 1–3/0 AWG, (6.6 kV, JIS) 35–70 mm², (6.6 kV, IEC) 14–38 mm², (8.0 kV, AEIC) 2–2/0 AWG, (10 kV, IEC) 10–50 mm², (15 kV, AEIC) 2–1 AWG,, (3.3 kV, JIS) 100–150 mm², (3.3 kV, JIS) 200–250 mm², (3.3 kV, JIS) 300–325 mm², (30 kV, IEC) 35–70 mm², (30 kV, IEC) 95–240 mm², (35 kV, AEIC) 1/0–3/0 AWG, (35 kV, AEIC) 4/0 AWG–500 kcmil, (5.0 kV, AEIC) 4/0 AWG–400 kcmil, (5.0 kV, AEIC) 500–750 kcmil, (5.0 kV, AEIC) 800–1000 kcmil, (6.6 kV, IEC) 150–250 mm², (6.6 kV, IEC) 300–325 mm², (6.6 kV, IEC) 60–100 mm², (6.6 kV, JIS) 185–300 mm², (6.6 kV, JIS) 95–150 mm², (8.0 kV, AEIC) 3/0 AWG–350 kcmil, (8.0 kV, AEIC) 400–600 kcmil, (8.0 kV, AEIC) 750–1000 kcmil
    Dielectric Strength (V/mil)
    428 V/mil
    Elongation
    910 %
    Inner Diameter Before Shrink (Imperial)
    0.6 in, 0.8 in, 1.02 in, 1.28 in, 1.62 in
    Insulation Rejacketing
    Yes
    Metallic Shield Diameter Range
    0.43 - 0.60 in, 0.60 - 0.80 in, 0.80 - 1.02 in, 1.02 - 1.28 in, 1.28 - 1.62 in
    Metallic Shield Diameter Range (Metric)
    10.9-15.2 mm, 15.2-20.3 mm, 20.3-25.9 mm, 25.9-32.5 mm, 32.5-41.1 mm
    Operating Temperature (Celsius)
    105
    Operating Temperature (Fahrenheit)
    194, 221 Degree Fahrenheit
    Overall Length (Imperial)
    10 ft, 4 ft
    Overall Length (Metric)
    304.8 m
    Product Type
    Splice Jacketing and Rejacketing Kits
    RoHS 2011/65/EU Compliant
    Undetermined
    RoHS EU Comments
    Contact 3M for information
    *Important RoHS information
    Temperature Rating
    356°F (180°C) Class H
    Tensile Strength (Imperial)
    1058 Pound-Force Per Square Inch
    Voltage Range
    3.3 - 15 kV, 3.3 - 25 kV, 3.3 - 35 kV, 3.3 - 8 kV