1. All 3M Products
  • 3M™ Molded Rubber QS-II Inline CN/JCN Cable Splice Kits 5450 Series
  • 3M™ Molded Rubber QS-II Inline CN/JCN Cable Splice Kits 5450 Series

    16  Products
    • Jacketing kit is required for JCN cable
    • Meets the requirements of IEEE 404 standards for cable joints
    • Computer design ensures a compact size and optimal distribution of the electrical field
    • Designed for direct burial installations, aerial installations and submerged locations
     More...
    Packaging
    Packaging
    16 Products Available
    Available options:
     Packaging
    All Options
    Close
    Specifications
    Attribute Name
    Value
    Agency Approvals
    ANSI/IEEE 404-1986
    Application
    Aerial Installations, Direct-Burial Installations, For Inline Splicing, Submerged Locations
    Application/Industry
    Utility
    Brand
    3M™
    Cable Shielding
    Concentric Neutral (CN), Jacketed Concentric Neutral (JCN)
    Case Quantity
    1
    Color Family
    Multi-Color
    Conductor Material
    Aluminum, Copper
    Conductor Size Range
    1 AWG, 1/0 AWG, 2 AWG, 2-1 AWG, 2-2/0 AWG, 3/0-4/0 AWG
    Conductor Sizes
    1 AWG, 1/0 AWG, 2 AWG, 2 to 2/0 AWG, 3/0 AWG, 4/0 AWG
    Conductor Sizes - Solid - Cable Insulation Thickness
    1 AWG(295 mils), 1/0 AWG (280 mils), 1/0 AWG (295 mils), 280 to 295 mil
    Conductor Sizes - Stranded - Cable Insulation Thickness
    1 AWG (280 mils), 1 AWG (295 mils), 1/0 AWG (260 mils), 1/0 AWG (280 mils), 1/0 AWG (295 mils), 2 AWG (295 mils), 2/0 AWG (260 mils), 2/0 AWG (280 mils), 280 to 295 mil
    Connector Included
    20006, CI-1/0-840, CI-1/0A, CI-1A, CI-2/0, CI-21-840, CI-2A, None
    Family
    5450
    Insulation Level
    100%, 133%
    Insulation O.D. Range
    0.775 - 0.90 Inch, 0.83 - 1.04 Inch, 0.905 - 1.055 Inch, 1.00 - 1.15 Inch
    Insulation Outer Diameter (Imperial)
    0.83 in, 0.84 in, 0.85 in, 0.86 in, 0.87 in, 0.88 in, 0.89 in, 0.9 in, 0.91 in, 0.92 in, 0.93 in, 0.94 in, 0.95 in, 0.96 in, 0.97 in, 0.98 in, 0.99 in, 1 in, 1.01 in, 1.02 in, 1.03 in, 1.04 in, 1.05 in, 1.06 in, 1.07 in, 1.08 in, 1.09 in, 1.1 in, 1.11 in, 1.12 in, 1.13 in, 1.14 in, 1.15 in
    Insulation Outer Diameter (Metric)
    21.082 mm, 21.336 mm, 21.59 mm, 21.844 mm, 22.098 mm, 22.352 mm, 22.606 mm, 22.86 mm, 23.114 mm, 23.368 mm, 23.622 mm, 23.876 mm, 24.13 mm, 24.384 mm, 24.638 mm, 24.892 mm, 25.146 mm, 25.4 mm, 25.654 mm, 25.908 mm, 26.162 mm, 26.416 mm, 26.67 mm, 26.924 mm, 27.178 mm, 27.432 mm, 27.686 mm, 27.94 mm, 28.194 mm, 28.448 mm, 28.702 mm, 28.956 mm, 29.21 mm
    Insulation Outside Diameter Range
    0.775 - 0.90 Inch, 0.83 - 1.04 Inch, 0.83 to 1.04 in, 0.905 - 1.055 Inch, 1.00 - 1.15 Inch
    Insulation Outside Diameter Range (Metric)
    19.7 - 22.9 mm, 21.1 - 26.4 mm, 21.1 to 26.4 mm, 23.0 - 26.8 mm, 25.4 - 29.2 mm
    Kit Includes
    (1) Instruction Sheet
    Manufacturing Origin
    USA
    Maximum Stranded Conductor Size
    2/0 AWG (175 mil)
    Number of Conductors
    1
    Operating Voltage
    15 kV, 25 kV, 28 kV
    Packaging
    1/Case
    Product Color
    Back, White
    Product Type
    Inline Splice, Splice
    Splice Type
    Inline
    Typical Splice Length
    14.4 in
    Typical Splice Length (Metric)
    366 mm
    Voltage
    25/28 kV
    Details
    • Jacketing kit is required for JCN cable
    • Meets the requirements of IEEE 404 standards for cable joints
    • Computer design ensures a compact size and optimal distribution of the electrical field
    • Designed for direct burial installations, aerial installations and submerged locations
    • Peroxide-cured EPDM rubber construction offers long term elastic memory

    The 3M™ Molded Rubber QS-II Inline CN/JCN Cable Splice Kits 5450 Series kits are one-piece inline splices designed for use on 25/28 kV CN and JCNcable. Meets requirements of IEEE 404 for cable joints. The splice is a one-piece molded design made of specially formulated, peroxide cured EPDM rubbers. Each splice is production tested on CN cable to ensure reliability. Each kit makes one splice. Jacketing kit is needed for JCN cable. Connectors, unless specfied, are not included in the kit, and must be ordered separately. Refer to the index to find CI, CI-840 and CI-A series connectors. Note: Cable sizes shown below are for standard insulation thickness. Final determining factor is cable insulation O.D.