Attribute Name
|
Value
|
---|---|
Brand
|
3M™
|
Cable Shielding
|
Jacketed Concentric Neutral (JCN), Tape Shield, UniShield®, Wire Shield
|
Cable Voltage Rating
|
15 kV, 25 kV, 5 kV, 8 kV
|
Color Family
|
Black, Gray
|
Conductor Size by Voltage
|
(15 kV, 100%) 1 AWG, Compact/Solid, (15 kV, 100%) 1 AWG, Stranded, (15 kV, 100%) 1/0 AWG, Compact/Solid, (15 kV, 100%) 1/0 AWG, Stranded, (15 kV, 100%) 1000 kcmil (Al), Stranded, (15 kV, 100%) 2 AWG, Stranded, (15 kV, 100%) 2/0 AWG, Compact/Solid, (15 kV, 100%) 2/0 AWG, Stranded, (15 kV, 100%) 250 kcmil, Compact/Solid, (15 kV, 100%) 250 kcmil, Stranded, (15 kV, 100%) 3/0 AWG, Compact/Solid, (15 kV, 100%) 3/0 AWG, Stranded, (15 kV, 100%) 350 kcmil, Stranded, (15 kV, 100%) 4/0 AWG, Compact/Solid, (15 kV, 100%) 4/0 AWG, Stranded, (15 kV, 100%) 500 kcmil, Stranded, (15 kV, 100%) 750 kcmil, Stranded, (15 kV, 133%) 1 AWG, Compact/Solid, (15 kV, 133%) 1 AWG, Stranded, (15 kV, 133%) 1/0 AWG, Compact/Solid, (15 kV, 133%) 1/0 AWG, Stranded, (15 kV, 133%) 1000 kcmil (Al), Stranded, (15 kV, 133%) 2 AWG, Stranded, (15 kV, 133%) 2/0 AWG, Compact/Solid, (15 kV, 133%) 2/0 AWG, Stranded, (15 kV, 133%) 250 kcmil, Compact/Solid, (15 kV, 133%) 250 kcmil, Stranded, (15 kV, 133%) 3/0 AWG, Compact/Solid, (15 kV, 133%) 3/0 AWG, Stranded, (15 kV, 133%) 350 kcmil, Stranded, (15 kV, 133%) 4/0 AWG, Compact/Solid, (15 kV, 133%) 4/0 AWG, Stranded, (15 kV, 133%) 500 kcmil, Stranded, (15 kV, 133%) 750 kcmil, Stranded, (25 kV, 100%) 1 AWG, Compact/Solid, (25 kV, 100%) 1 AWG, Stranded, (25 kV, 100%) 1/0 AWG, Compact/Solid, (25 kV, 100%) 1/0 AWG, Stranded, (25 kV, 100%) 1000 kcmil (Al), Stranded, (25 kV, 100%) 2 AWG, Stranded, (25 kV, 100%) 2/0 AWG, Compact/Solid, (25 kV, 100%) 250 kcmil, Compact/Solid, (25 kV, 100%) 250 kcmil, Stranded, (25 kV, 100%) 3/0 AWG, Stranded, (25 kV, 100%) 350 kcmil, Stranded, (25 kV, 100%) 4/0 AWG, Compact/Solid, (25 kV, 100%) 4/0 AWG, Stranded, (25 kV, 100%) 500 kcmil, Stranded, (25 kV, 133%) 1/0 AWG, Stranded, (25 kV, 133%) 1000 kcmil (Al), Stranded, (25 kV, 133%) 2/0 AWG, Compact/Solid, (25 kV, 133%) 250 kcmil, Compact/Solid, (25 kV, 133%) 250 kcmil, Stranded, (25 kV, 133%) 350 kcmil, Stranded, (25 kV, 133%) 4/0 AWG, Stranded, (25 kV, 133%) 500 kcmil, Stranded, (25 kV, 133%) 750 kcmil, Stranded, (5 kV, 100%) 250 kcmil, Compact/Solid, (5 kV, 100%) 250 kcmil, Stranded, (5 kV, 100%) 3/0 AWG, Stranded, (5 kV, 100%) 350 kcmil, Stranded, (5 kV, 100%) 4/0 AWG, Compact/Solid, (5 kV, 100%) 4/0 AWG, Stranded, (5 kV, 100%) 500 kcmil, Stranded, (5 kV, 133%) 1000 kcmil (Al), Stranded, (5 kV, 133%) 250 kcmil, Compact/Solid, (5 kV, 133%) 250 kcmil, Stranded, (5 kV, 133%) 3/0 AWG, Stranded, (5 kV, 133%) 350 kcmil, Stranded, (5 kV, 133%) 4/0 AWG, Compact/Solid, (5 kV, 133%) 4/0 AWG, Stranded, (5 kV, 133%) 500 kcmil, Stranded, (5 kV, 133%) 750 kcmil, Stranded, (8 kV, 100%) 1000 kcmil (Al), Stranded, (8 kV, 100%) 250 kcmil, Compact/Solid, (8 kV, 100%) 250 kcmil, Stranded, (8 kV, 100%) 3/0 AWG, Stranded, (8 kV, 100%) 350 kcmil, Stranded, (8 kV, 100%) 4/0 AWG, Compact/Solid, (8 kV, 100%) 4/0 AWG, Stranded, (8 kV, 100%) 500 kcmil, Stranded, (8 kV, 100%) 750 kcmil, Stranded, (8 kV, 133%) 1000 kcmil (Al), Stranded, (8 kV, 133%) 2/0 AWG, Stranded, (8 kV, 133%) 250 kcmil, Compact/Solid, (8 kV, 133%) 250 kcmil, Stranded, (8 kV, 133%) 3/0 AWG, Stranded, (8 kV, 133%) 350 kcmil, Stranded, (8 kV, 133%) 4/0 AWG, Compact/Solid, (8 kV, 133%) 4/0 AWG, Stranded, (8 kV, 133%) 500 kcmil, Stranded, (8 kV, 133%) 750 kcmil, Stranded
|
Conductor Sizes
|
1 AWG, 1/0 AWG, 1000 kcmil, 2 AWG, 2/0 AWG, 250 kcmil, 3/0 AWG, 350 kcmil, 4/0 AWG, 500 kcmil, 750 kcmil
|
Current Rating
|
600 Ampere
|
Dielectric Strength (V/mil)
|
428 V/mil
|
Elongation
|
910 %
|
Family
|
3M™ Cable Adapter Kit, 3M™ Modular Splicing Kit
|
Insulation Diameter Range
|
0.630-0.820 in, 0.640-0.760 in, 0.700-0.910 in, 0.720-0.845 in, 0.785-0.970 in, 0.850-1.100 in, 0.910-1.065 in, 0.980-1.140 in, 1.040-1.250 in, 1.080-1.280 in, 1.220-1.420 in, 1.360-1.560 in, 1.480-1.700 in, 1.640-1.840 in
|
Insulation Diameter Range (Metric)
|
16.0-20.8 mm, 16.3-19.3 mm, 17.8-23.1 mm, 18.3-21.5 mm, 19.9-24.6 mm, 21.6-27.9 mm, 23.1-27.1 mm, 24.9-29.0 mm, 26.4-31.8 mm, 27.4-32.5 mm, 31.0-36.1 mm, 34.5-39.6 mm, 37.6-43.2 mm, 41.7-46.7 mm
|
Insulation Level
|
100%, 133%
|
Manufacturing Origin
|
USA
|
Maximum Insulation Outer Diameter (Imperial)
|
0.076 in, 0.76 in, 0.845 in, 0.97 in, 1.065 in, 1.14 in, 1.28 in, 1.42 in, 1.56 in, 1.7 in, 1.84 in, 1.965 in
|
Maximum Insulation Outer Diameter (Metric)
|
19 mm, 2 mm, 21 mm, 25 mm, 27 mm, 29 mm, 33 mm, 36 mm, 40 mm, 43 mm, 47 mm, 50 mm
|
Maximum Operating Voltage
|
15 kV, 25 kV, 5 kV, 8 kV
|
Metallic Shield Diameter Range
|
0.43-0.60 in, 0.60-0.80 in, 0.80-1.02 in, 1.28-1.62 in
|
Operating Temperature (Celsius)
|
90
|
Operating Temperature (Fahrenheit)
|
194
|
Overall Length (Imperial)
|
10 ft
|
Overall Length (Metric)
|
3.05 m
|
Product Color
|
Black, Dark Gray
|
Product Type
|
Splice
|
Separable Connector Type
|
Dead Break Elbows
|
Splice Type
|
Modular
|
Temperature Rating
|
356°F (180°C) Class H
|
Tensile Strength (Imperial)
|
1058 Pound-Force Per Square Inch
|
Units per Case
|
1
|
3M™ Modular Splicing Kit 5815 is a fully shielded separable connector system. It allows a complete dead front connection that is suitable for operating in submerged or locations. This kit is used with the 3M Modular Splicing System 5815 Series that is rated for 5 to 25 kV and 600 amp industrial shielded power cables.
3M™ Modular Splicing Kit 5815 includes 1 cable adapter, 1 aluminum compressed connector, 1 cold shrink jacketing tube, 2 silicone lubricants and more. It provides installation information for wire shield, tape shield, UniShield® and jacketed concentric, neutral type solid dielectric cables. For use with 5815 kits to provide for It is suitable for dead ending, splicing and connecting to dead front apparatus like switches, switchgear and transformers that are equipped with bushings. It has an insulating plug that provides a safe means of testing the circuit without disturbing the bolted connection. Simply adding or removing modular components helps the system for future modification. Meets ANSI/IEEE Standard 386.