1. All 3M Products

3M™ Cold Shrink Three Conductor Breakout Kits

Products
Cable Insulation Outside Diameter Range
Conductor Size by Voltage
Products Available
Available options:
 Cable Insulation Outside Diameter Range and Conductor Size by Voltage
All Options
  • Cable Insulation Outside Diameter Range
    Conductor Size by Voltage
  • 0.33-0.50 in
    (5 kV, 100%) 8–2 AWG, (5 kV, 133%) 6–4 AWG, (8 kV, 100%) 6–4 AWG, (8 kV, 133%) 6–4 AWG
  • 0.50-0.70 in
    (5 kV, 100%) 1–3/0 AWG, (5 kV, 133%) 2–2/0 AWG, (8 kV, 100%) 2–2/0 AWG, (8 kV, 133%) 2–2/0 AWG, (15 kV, 100%) 2–1 AWG
  • 0.70-0.92 in
    (5 kV, 100%) 4/0 AWG–350 kcmil(5 kV, 133%) 3/0 AWG–350 kcmil(8 kV, 100%) 3/0 AWG–350 kcmil(8 kV, 133%) 3/0 AWG–350 kcmil(15 kV, 100%) 1/0–4/0 AWG(15 kV, 133%) 2–3/0 AWG, (25/28 kV, 100%) 1–1/0 AWG
  • 0.92-1.18 in
    (5 kV, 100%) 400–500 kcmil, (5 kV, 133%) 400–500 kcmil, (8 kV, 100%) 400–500 kcmil, (8 kV, 133%) 400–500 kcmil, (15 kV, 100%) 250–350 kcmil, (15 kV, 133%) 4/0 AWG–350 kcmil, (25/28 kV, 100%) 2/0 AWG–250 kcmil, (25/28 kV, 133%) 1–4/0 AWG,
  • 1.18-1.52 in
    (15 kV, 100%) 500–750 kcmil, (15 kV, 133%) 500–750 kcmil, (25/28 kV, 100%) 350–500 kcmil, (25/28 kV, 133%) 250–500 kcmil, (35 kV, 100%) 4/0 AWG–500 kcmil, (35 kV, 133%) 1/0 AWG–350 kcmil, (5 kV, 100%) 700–1000 kcmil, (5 kV, 133%) 700–1000 kcmil, (8 kV, 100%) 700–1000 kcmil, (8 kV, 133%) 700–1000 kcmil
  • 1.53-1.81 in
    (15 kV, 100%) 1000 kcmil, (15 kV, 133%) 1000 kcmil, (25/28 kV, 100%) 750 kcmil, (25/28 kV, 133%) 500–750 kcmil, (35 kV, 100%) 500–750 kcmil, (35 kV, 133%) 350–750 kcmil
  • Cable Insulation Outside Diameter Range
    Conductor Size by Voltage
  • Cable Insulation Outside Diameter Range
    0.33-0.50 in
    Conductor Size by Voltage
    (5 kV, 100%) 8–2 AWG, (5 kV, 133%) 6–4 AWG, (8 kV, 100%) 6–4 AWG, (8 kV, 133%) 6–4 AWG
  • Cable Insulation Outside Diameter Range
    0.50-0.70 in
    Conductor Size by Voltage
    (5 kV, 100%) 1–3/0 AWG, (5 kV, 133%) 2–2/0 AWG, (8 kV, 100%) 2–2/0 AWG, (8 kV, 133%) 2–2/0 AWG, (15 kV, 100%) 2–1 AWG
  • Cable Insulation Outside Diameter Range
    0.70-0.92 in
    Conductor Size by Voltage
    (5 kV, 100%) 4/0 AWG–350 kcmil(5 kV, 133%) 3/0 AWG–350 kcmil(8 kV, 100%) 3/0 AWG–350 kcmil(8 kV, 133%) 3/0 AWG–350 kcmil(15 kV, 100%) 1/0–4/0 AWG(15 kV, 133%) 2–3/0 AWG, (25/28 kV, 100%) 1–1/0 AWG
  • Cable Insulation Outside Diameter Range
    0.92-1.18 in
    Conductor Size by Voltage
    (5 kV, 100%) 400–500 kcmil, (5 kV, 133%) 400–500 kcmil, (8 kV, 100%) 400–500 kcmil, (8 kV, 133%) 400–500 kcmil, (15 kV, 100%) 250–350 kcmil, (15 kV, 133%) 4/0 AWG–350 kcmil, (25/28 kV, 100%) 2/0 AWG–250 kcmil, (25/28 kV, 133%) 1–4/0 AWG,
  • Cable Insulation Outside Diameter Range
    1.18-1.52 in
    Conductor Size by Voltage
    (15 kV, 100%) 500–750 kcmil
  • Cable Insulation Outside Diameter Range
    1.53-1.81 in
    Conductor Size by Voltage
    (15 kV, 100%) 1000 kcmil, (15 kV, 133%) 1000 kcmil, (25/28 kV, 100%) 750 kcmil, (25/28 kV, 133%) 500–750 kcmil, (35 kV, 100%) 500–750 kcmil, (35 kV, 133%) 350–750 kcmil
Close
Specifications
Attribute Name
Value
Brand
3M™
Breakout Boot
Yes
Cable Accessory Products
Cable Breakout Boot Kits
Cable Insulation Outside Diameter Range
0.33-0.50 in, 0.50-0.70 in, 0.70-0.92 in, 0.92-1.18 in, 1.18-1.52 in, 1.53-1.81 in
Cable Insulation Outside Diameter Range (Metric)
12.7-17.8 mm, 17.8-23.4 mm, 23.4-30.0 mm, 30.0-38.6 mm, 38.8-46.0 mm, 8.4-12.7 mm
Case Quantity
1
Conductor Size by Voltage
(15 kV, 100%) 1000 kcmil, (15 kV, 133%) 1000 kcmil, (25/28 kV, 100%) 750 kcmil, (25/28 kV, 133%) 500–750 kcmil, (35 kV, 100%) 500–750 kcmil, (35 kV, 133%) 350–750 kcmil, (15 kV, 100%) 500–750 kcmil, (15 kV, 133%) 500–750 kcmil, (25/28 kV, 100%) 350–500 kcmil, (25/28 kV, 133%) 250–500 kcmil, (35 kV, 100%) 4/0 AWG–500 kcmil, (35 kV, 133%) 1/0 AWG–350 kcmil, (5 kV, 100%) 1–3/0 AWG, (5 kV, 133%) 2–2/0 AWG, (8 kV, 100%) 2–2/0 AWG, (8 kV, 133%) 2–2/0 AWG, (15 kV, 100%) 2–1 AWG, (5 kV, 100%) 4/0 AWG–350 kcmil(5 kV, 133%) 3/0 AWG–350 kcmil(8 kV, 100%) 3/0 AWG–350 kcmil(8 kV, 133%) 3/0 AWG–350 kcmil(15 kV, 100%) 1/0–4/0 AWG(15 kV, 133%) 2–3/0 AWG, (25/28 kV, 100%) 1–1/0 AWG, (5 kV, 100%) 400–500 kcmil, (5 kV, 133%) 400–500 kcmil, (8 kV, 100%) 400–500 kcmil, (8 kV, 133%) 400–500 kcmil, (15 kV, 100%) 250–350 kcmil, (15 kV, 133%) 4/0 AWG–350 kcmil, (25/28 kV, 100%) 2/0 AWG–250 kcmil, (25/28 kV, 133%) 1–4/0 AWG,, (5 kV, 100%) 700–1000 kcmil, (5 kV, 100%) 8–2 AWG, (5 kV, 133%) 6–4 AWG, (8 kV, 100%) 6–4 AWG, (8 kV, 133%) 6–4 AWG, (5 kV, 133%) 700–1000 kcmil, (8 kV, 100%) 700–1000 kcmil, (8 kV, 133%) 700–1000 kcmil
Conductor Size for 15 kV at 100% Insulation
1/0–4/0, 1000, 250–350, 2–1, 500–750
Conductor Size for 15 kV at 133% Insulation
1000, 2–3/0, 4/0–350, 500–750
Conductor Size for 25/28 kV at 100% Insulation
1–1/0, 2/0–250, 350–500, 750
Conductor Size for 25/28 kV at 133% Insulation
1–4/0, 250–500, 500–750
Conductor Size for 35 kV at 100% Insulation
4/0–500, 500–750
Conductor Size for 35 kV at 133% Insulation
1/0–350, 350–750
Conductor Size for 5 kV at 100% Insulation
1–3/0, 4/0–350, 400–500, 700–1000, 8–2
Conductor Size for 5 kV at 133% Insulation
2–2/0, 3/0–350, 400–500, 6–4, 700–1000
Conductor Size for 8 kV at 100% Insulation
2–2/0, 3/0–350, 400–500, 6–4, 700–1000
Conductor Size for 8 kV at 133% Insulation
2–2/0, 3/0–350, 400–500, 6–4, 700–1000
Insulation Rejacketing
Yes
Maximum Cable Outside Diameter
1.94 in, 2.67 in, 3.1 in, 4.32 in, 4.7 in, 5.52 in
Maximum Cable Outside Diameter (Metric)
109.7 mm, 119.4 mm, 140.2 mm, 49.3 mm, 67.8 mm, 78.7 mm
Number of Conductors
3
RoHS 2011/65/EU Compliant
Undetermined
RoHS EU Comments
Contact 3M for information