    Specifications
    Attribute Name
    Value
    Brand
    3M™
    Breakout Boot
    Yes
    Cable Accessory Products
    Cable Breakout Boot Kits
    Cable Insulation Outside Diameter Range
    0.33-0.50 in, 0.50-0.70 in, 0.70-0.92 in, 0.92-1.18 in, 1.18-1.52 in, 1.53-1.81 in
    Cable Insulation Outside Diameter Range (Metric)
    12.7-17.8 mm, 17.8-23.4 mm, 23.4-30.0 mm, 30.0-38.6 mm, 38.8-46.0 mm, 8.4-12.7 mm
    Case Quantity
    1
    Conductor Size by Voltage
    (15 kV, 100%) 1000 kcmil, (15 kV, 133%) 1000 kcmil, (25/28 kV, 100%) 750 kcmil, (25/28 kV, 133%) 500–750 kcmil, (35 kV, 100%) 500–750 kcmil, (35 kV, 133%) 350–750 kcmil, (15 kV, 100%) 500–750 kcmil, (15 kV, 133%) 500–750 kcmil, (25/28 kV, 100%) 350–500 kcmil, (25/28 kV, 133%) 250–500 kcmil, (35 kV, 100%) 4/0 AWG–500 kcmil, (35 kV, 133%) 1/0 AWG–350 kcmil, (5 kV, 100%) 1–3/0 AWG, (5 kV, 133%) 2–2/0 AWG, (8 kV, 100%) 2–2/0 AWG, (8 kV, 133%) 2–2/0 AWG, (15 kV, 100%) 2–1 AWG, (5 kV, 100%) 4/0 AWG–350 kcmil(5 kV, 133%) 3/0 AWG–350 kcmil(8 kV, 100%) 3/0 AWG–350 kcmil(8 kV, 133%) 3/0 AWG–350 kcmil(15 kV, 100%) 1/0–4/0 AWG(15 kV, 133%) 2–3/0 AWG, (25/28 kV, 100%) 1–1/0 AWG, (5 kV, 100%) 400–500 kcmil, (5 kV, 133%) 400–500 kcmil, (8 kV, 100%) 400–500 kcmil, (8 kV, 133%) 400–500 kcmil, (15 kV, 100%) 250–350 kcmil, (15 kV, 133%) 4/0 AWG–350 kcmil, (25/28 kV, 100%) 2/0 AWG–250 kcmil, (25/28 kV, 133%) 1–4/0 AWG,, (5 kV, 100%) 700–1000 kcmil, (5 kV, 100%) 8–2 AWG, (5 kV, 133%) 6–4 AWG, (8 kV, 100%) 6–4 AWG, (8 kV, 133%) 6–4 AWG, (5 kV, 133%) 700–1000 kcmil, (8 kV, 100%) 700–1000 kcmil, (8 kV, 133%) 700–1000 kcmil
    Conductor Size for 15 kV at 100% Insulation
    1/0–4/0, 1000, 250–350, 2–1, 500–750
    Conductor Size for 15 kV at 133% Insulation
    1000, 2–3/0, 4/0–350, 500–750
    Conductor Size for 25/28 kV at 100% Insulation
    1–1/0, 2/0–250, 350–500, 750
    Conductor Size for 25/28 kV at 133% Insulation
    1–4/0, 250–500, 500–750
    Conductor Size for 35 kV at 100% Insulation
    4/0–500, 500–750
    Conductor Size for 35 kV at 133% Insulation
    1/0–350, 350–750
    Conductor Size for 5 kV at 100% Insulation
    1–3/0, 4/0–350, 400–500, 700–1000, 8–2
    Conductor Size for 5 kV at 133% Insulation
    2–2/0, 3/0–350, 400–500, 6–4, 700–1000
    Conductor Size for 8 kV at 100% Insulation
    2–2/0, 3/0–350, 400–500, 6–4, 700–1000
    Conductor Size for 8 kV at 133% Insulation
    2–2/0, 3/0–350, 400–500, 6–4, 700–1000
    Insulation Rejacketing
    Yes
    Maximum Cable Outside Diameter
    1.94 in, 2.67 in, 3.1 in, 4.32 in, 4.7 in, 5.52 in
    Maximum Cable Outside Diameter (Metric)
    109.7 mm, 119.4 mm, 140.2 mm, 49.3 mm, 67.8 mm, 78.7 mm
    Number of Conductors
    3
    RoHS 2011/65/EU Compliant
    Undetermined
    RoHS EU Comments
    Contact 3M for information
    *Important RoHS information