1. All 3M Products
  • 3M™ Cold Shrink QT-III Three Conductor Cable Termination Kit 7622-T-125-3-RJS, Tape, Wire and UniShield®, 20 kV, 0.70-0.92 in (17,8-23,4 mm) Cable Insul. O.D., 3 terminations/kit
  • 3M™ Cold Shrink QT-III Three Conductor Cable Termination Kit 7622-T-125-3-RJS, Tape, Wire and UniShield®, 20 kV, 0.70-0.92 in (17,8-23,4 mm) Cable Insul. O.D., 3 terminations/kit

    Part Number 7622-T-125-3-RJS3M ID 80610988257UPC 00054007047148
    • Provides a void-free seal to tape shield, wire shield and UniShield® power cables
    • High dielectric-constant material regulates the distribution of electric field stress
    • Suitable for indoor applications and cabinet-mount installations
    • Termination has 0.70 to 0.92-in insulation O.D.
     More...
    Specifications
    Attribute Name
    Value
    Agency Approvals
    AEIC, IEC, JIS
    Breakout Boot
    No
    Cable Insulation Outside Diameter Range
    0.70-0.92 in
    Cable Insulation Outside Diameter Range (Metric)
    17.8-23.4 mm
    Cable Shielding
    Tape Shield, UniShield®, Wire Shield
    Conductor Size by Voltage
    (5 kV) 4/0 AWG-400 kcmil, (8 kV) 3/0 AWG-350 kcmil, (15 kV) 1/0-4/0 AWG
    Conductor Sizes
    1/0 AWG, 2/0 AWG, 250 kcmil, 3/0 AWG, 300 kcmil, 350 kcmil, 4/0 AWG, 400 kcmil
    Family
    QT-III
    Indoor/Outdoor
    Indoor Non-skirted
    Insulation Level
    100%, 133%
    Insulation Outer Diameter (Imperial)
    0.71 in, 0.72 in, 0.73 in, 0.74 in, 0.75 in, 0.76 in, 0.77 in, 0.78 in, 0.79 in, 0.8 in, 0.81 in, 0.82 in, 0.83 in, 0.84 in, 0.85 in, 0.86 in, 0.87 in, 0.88 in, 0.89 in, 0.9 in, 0.91 in, 0.92 in
    Insulation Rejacketing
    Yes
    Lug/Stem Connector Included in Kit
    No
    Maximum Installed Length
    10.50 in
    Number of Conductors
    3
    Voltage
    15 kV, 5 kV, 8 kV
    Details
    • Provides a void-free seal to tape shield, wire shield and UniShield® power cables
    • High dielectric-constant material regulates the distribution of electric field stress
    • Suitable for indoor applications and cabinet-mount installations
    • Termination has 0.70 to 0.92-in insulation O.D.
    • Accommodates wire sizes of 4/0 AWG to 400 kcmil at 5kV, 3/0 AWG to 350 kcmil at 8 kV, 35 to 95 mm² at 15kV
    • Integrated design allows for easier installation, while sealing compounds provide constant radial pressure
    • Withstands voltages of 5 to 35kV and is 125kV BIL-rated
    • Includes a 3-phase, cold shrink termination
    • JIS,‎ IEC and AEIC Approved

    3M™ Cold Shrink QT-III 7600-T-3-RJS Series Termination Kit includes a non-skirted, 3-phase termination. It ensures a pliable, tight seal for tape shield, wire shield and UniShield® power cables. The conjunction of high dielectric-constant material and sealing compounds allows the termination to withstand voltages of 5 to 35kV.

    3M™ Cold Shrink QT-III 7600-T-3-RJS Series Termination Kit is designed for terminating medium voltage cables with or without internal ground wires. The UV stable, track-resistant construction makes the termination suitable for indoor applications. The lower surface stress, high dielectric-constant material offers an optimized BIL performance while ensuring a leak-proof, compact fit. ‎ JIS,‎ IEC and AEIC Approved.

    Conductor Size Range for
    · 5 kV: 4/0 AWG-400 kcmil
    · 8 kV: 3/0 AWG-350 kcmil
    · 15 kV: 1/0-4/0 AWG

    Follow Us
    The brands listed above are trademarks of 3M.
    Change Location
    United States - English