1. All 3M Products
  • 3M™ Cold Shrink QT-III Termination Kit 7695-T-150, Tape/Wire/UniShield® Shielding, 5-35 kV, Insulation OD 1.05-1.80 in, 3/kit
  • 3M™ Cold Shrink QT-III Termination Kit 7695-T-150, Tape/Wire/UniShield® Shielding, 5-35 kV, Insulation OD 1.05-1.80 in, 3/kit

    Part Number 7695-T-1503M ID 80610834287UPC 00054007417798
    • Provides a void-free seal to tape shield, wire shield and UniShield® power cables
    • High dielectric-constant material regulates the distribution of electric field stress
    • Suitable for indoor applications
    • Non-tracking, molded, silicone rubber insulation offers durability
     More...
    View Legal Disclaimer
    Specifications
    Attribute Name
    Value
    Agency Approvals
    IEEE
    BIL
    150 kV
    Brand
    3M™
    Breakout Boot
    No
    Cable Insulation Outside Diameter Range
    1.05-1.80 in
    Cable Insulation Outside Diameter Range (Metric)
    26.7-45.7 mm
    Cable Shielding
    Tape Shield, UniShield®, Wire Shield
    Case Quantity
    1
    Compatible Lug
    QL2-A-350-750, QL2-A-4/0-600
    Conductor Size by Voltage
    (5 kV) 700-1500 kcmil, (8 kV) 600-1250 kcmil, (15 kV) 500-1000 kcmil, (25/28 kV) 250-800 kcmil, (35 kV) 3/0 AWG-600 kcmil
    Conductor Sizes
    1000 kcmil, 1250 kcmil, 1500 kcmil, 250 kcmil, 3/0 AWG, 300 kcmil, 350 kcmil, 4/0 AWG, 400 kcmil, 500 kcmil, 600 kcmil, 700 kcmil, 750 kcmil, 800 kcmil, 900 kcmil
    Family
    QT-III
    Indoor/Outdoor
    Indoor Non-skirted
    Insulation Level
    100%, 133%
    Insulation Outer Diameter (Imperial)
    1.05 in, 1.06 in, 1.07 in, 1.08 in, 1.09 in, 1.1 in, 1.11 in, 1.12 in, 1.13 in, 1.14 in, 1.15 in, 1.16 in, 1.17 in, 1.18 in, 1.19 in, 1.2 in, 1.21 in, 1.22 in, 1.23 in, 1.24 in, 1.25 in, 1.26 in, 1.27 in, 1.28 in, 1.29 in, 1.3 in, 1.31 in, 1.32 in, 1.33 in, 1.34 in, 1.35 in, 1.36 in, 1.37 in, 1.38 in, 1.39 in, 1.4 in, 1.41 in, 1.42 in, 1.43 in, 1.44 in, 1.45 in, 1.46 in, 1.47 in, 1.48 in, 1.49 in, 1.5 in, 1.51 in, 1.52 in, 1.53 in, 1.54 in, 1.55 in, 1.56 in, 1.57 in, 1.58 in, 1.59 in, 1.6 in, 1.61 in, 1.62 in, 1.63 in, 1.64 in, 1.65 in, 1.66 in, 1.67 in, 1.68 in, 1.69 in, 1.7 in, 1.71 in, 1.72 in, 1.73 in, 1.74 in, 1.75 in, 1.76 in, 1.77 in, 1.78 in, 1.79 in, 1.8 in
    Insulation Outer Diameter (Metric)
    26.67 mm, 26.924 mm, 27.178 mm, 27.432 mm, 27.686 mm, 27.94 mm, 28.194 mm, 28.448 mm, 28.702 mm, 28.956 mm, 29.21 mm, 29.464 mm, 29.718 mm, 29.972 mm, 30.226 mm, 30.48 mm, 30.734 mm, 30.988 mm, 31.242 mm, 31.496 mm, 31.75 mm, 32.004 mm, 32.258 mm, 32.512 mm, 32.766 mm, 33.02 mm, 33.274 mm, 33.528 mm, 33.782 mm, 34.036 mm, 34.29 mm, 34.544 mm, 34.798 mm, 35.052 mm, 35.306 mm, 35.56 mm, 35.814 mm, 36.068 mm, 36.322 mm, 36.576 mm, 36.83 mm, 37.084 mm, 37.338 mm, 37.592 mm, 37.846 mm, 38.1 mm, 38.354 mm, 38.608 mm, 38.862 mm, 39.116 mm, 39.37 mm, 39.624 mm, 39.878 mm, 40.132 mm, 40.386 mm, 40.64 mm, 40.894 mm, 41.148 mm, 41.402 mm, 41.656 mm, 41.91 mm, 42.164 mm, 42.418 mm, 42.672 mm, 42.926 mm, 43.18 mm, 43.434 mm, 43.688 mm, 43.942 mm, 44.196 mm, 44.45 mm, 44.704 mm, 44.958 mm, 45.212 mm, 45.466 mm, 45.72 mm
    Insulation Rejacketing
    No
    Lug/Stem Connector Included in Kit
    No
    Maximum Installed Length
    16.00 in
    Number of Conductors
    1
    Product Series
    7690-T
    RoHS 2011/65/EU Compliant
    Undetermined
    RoHS EU Comments
    Contact 3M for information
    *Important RoHS information
    Voltage
    15 kV, 25/28 kV, 35 kV, 5 kV, 8 kV
    Voltage Application
    Medium Voltage
    Details
    • Provides a void-free seal to tape shield, wire shield and UniShield® power cables
    • High dielectric-constant material regulates the distribution of electric field stress
    • Suitable for indoor applications
    • Non-tracking, molded, silicone rubber insulation offers durability
    • Includes 3 non-skirted, 1-piece, 3-phase, cold shrink terminations

    3M™ Cold Shrink QT-III Silicone Rubber Termination Kit 7620-T and 7690-T Series contains one-piece, non-skirted, silicone rubber terminations, meets IEEE Standard 48 Class 1 for indoor and weather-protected applications. The kits are designed for terminating solid dielectric shielded power cable rated 5–35 kV, with tape shield, wire shield and UniShield® constructions.

    Each kit contains sufficient quantities of material to make three single-phase terminations. The termination assemblies consist of a tubular insulator, high dielectric constant (Hi-K) stress control tube, conformable Hi-K stress controlling compound, and built-in environmental top seal. The insulator is made of a dark gray silicone rubber with advanced tracking resistant and hydrophobic properties. Note: Lugs need to be ordered separately. Exceptions: For T-150 Kits, 150 kV impulse level meets the impulse requirements for 35 kV class equipment where indoor terminations are used. 7620-T Kits are designed and assembled with stress controlling compound only.