1. All 3M Products
  • 3M™ Cold Shrink QT-III 3/C Termination Kit 7695-T-150-3G, Tape/Wire/UniShield®, 5-35 kV, Insulation OD 1.18-1.51 in, 3/kit
  • 3M™ Cold Shrink QT-III 3/C Termination Kit 7695-T-150-3G, Tape/Wire/UniShield®, 5-35 kV, Insulation OD 1.18-1.51 in, 3/kit

    Part Number 7695-T-150-3G3M ID 80611202757UPC 00054007436751
    • Provides a void-free seal to tape shield, wire shield and UniShield® power cables
    • High dielectric-constant material regulates the distribution of electric field stress
    • Suitable for indoor applications
    • Silicone rubber insulation offers durability and reduces leakage currents in damp conditions
     More...
    View Legal Disclaimer
    Specifications
    Attribute Name
    Value
    Agency Approvals
    IEEE
    Brand
    3M™
    Breakout Boot
    Yes
    Cable Insulation Outside Diameter Range
    1.18-1.52 in
    Cable Insulation Outside Diameter Range (Metric)
    30.0-38.6 mm
    Cable Shielding
    Tape Shield, UniShield®, Wire Shield
    Case Quantity
    1
    Conductor Size by Voltage
    (15 kV, 100%) 500-750 kcmil, (15 kV, 133%) 500-750 kcmil, (25/28 kV, 100%) 350-500 kcmil, (25/28 kV, 133%) 250-500 kcmil, (35 kV, 100%) 4/0 AWG-500 kcmil, (35 kV, 133%) 1/0 AWG-350 kcmil, (5 kV, 100%) 700-1000 kcmil, (5 kV, 133%) 700-1000 kcmil, (8 kV, 100%) 700-1000 kcmil, (8 kV, 133%) 700-1000 kcmil
    Conductor Sizes
    1/0 AWG, 1000 kcmil, 2/0 AWG, 250 kcmil, 3/0 AWG, 300 kcmil, 350 kcmil, 4/0 AWG, 400 kcmil, 500 kcmil, 600 kcmil, 700 kcmil, 750 kcmil, 800 kcmil, 900 kcmil
    Family
    QT-III
    Indoor/Outdoor
    Indoor Non-skirted
    Insulation Level
    100%, 133%
    Insulation Outer Diameter (Imperial)
    1.18 in, 1.19 in, 1.2 in, 1.21 in, 1.22 in, 1.23 in, 1.24 in, 1.25 in, 1.26 in, 1.27 in, 1.28 in, 1.29 in, 1.3 in, 1.31 in, 1.32 in, 1.33 in, 1.34 in, 1.35 in, 1.36 in, 1.37 in, 1.38 in, 1.39 in, 1.4 in, 1.41 in, 1.42 in, 1.43 in, 1.44 in, 1.45 in, 1.46 in, 1.47 in, 1.48 in, 1.49 in, 1.5 in, 1.51 in, 1.52 in
    Insulation Outer Diameter (Metric)
    29.972 mm, 30.226 mm, 30.48 mm, 30.734 mm, 30.988 mm, 31.242 mm, 31.496 mm, 31.75 mm, 32.004 mm, 32.258 mm, 32.512 mm, 32.766 mm, 33.02 mm, 33.274 mm, 33.528 mm, 33.782 mm, 34.036 mm, 34.29 mm, 34.544 mm, 34.798 mm, 35.052 mm, 35.306 mm, 35.56 mm, 35.814 mm, 36.068 mm, 36.322 mm, 36.576 mm, 36.83 mm, 37.084 mm, 37.338 mm, 37.592 mm, 37.846 mm, 38.1 mm, 38.354 mm, 38.608 mm
    Insulation Rejacketing
    Yes
    Lug/Stem Connector Included in Kit
    No
    Manufacturing Origin
    USA
    Maximum Cable Outside Diameter
    4.50 in
    Maximum Cable Outside Diameter (Metric)
    114.3 mm
    Maximum Installed Length
    16.00 in
    Number of Conductors
    3
    Voltage
    15 kV, 25 kV, 35 kV, 5 kV, 8 kV
    Voltage Application
    Medium Voltage
    Details
    • Provides a void-free seal to tape shield, wire shield and UniShield® power cables
    • High dielectric-constant material regulates the distribution of electric field stress
    • Suitable for indoor applications
    • Silicone rubber insulation offers durability and reduces leakage currents in damp conditions

    3M™ Cold Shrink QT III 7600 T 3G Series Termination Kit includes a non skirted, 3 phase termination. It ensures a pliable, tight seal for tape shield, wire shield and UniShield® power cables. The silicone rubber sealing compounds allow the termination to withstand voltages of 5 to 35kV.

    Legal Disclaimer

    Manufacturing Origin: USA

    The designation that a product is Manufactured in the USA means the product undergoes substantial transformation in one of our U.S. Manufacturing plants. Some products contain imported components.

    Note: 3M products offered on a government contract that require country of origin representation must be certified by 3M Trade Compliance. Contact customer service at 800-245-3573 to request a certificate.
    Follow Us
    The brands listed above are trademarks of 3M.
    Change Location
    United States - English