1. All 3M Products
  • 3M™ Cold Shrink QT-II Outdoor Termination Kit 5606, CN Shielding, 5-35 kV, 1.08-1.80 in (27-46 mm) Cable Insul. O.D., 1/kit
  • 3M™ Cold Shrink QT-II Outdoor Termination Kit 5606, CN Shielding, 5-35 kV, 1.08-1.80 in (27-46 mm) Cable Insul. O.D., 1/kit

    Part Number 56063M ID 80610154835UPC 00054007118930
    • One-piece cold shrink termination.
    • High dielectric-constant material regulates the distribution of electric field stress
    • Suitable for outdoor, weather exposed applications
    • Silicone rubber insulation is track-resistance and hydrophobic
     More...
    View Legal Disclaimer
    Specifications
    Attribute Name
    Value
    Agency Approvals
    IEEE
    BIL
    200 kV
    Brand
    3M™
    Breakout Boot
    No
    Cable Insulation Outside Diameter Range
    1.08-1.80 in
    Cable Insulation Outside Diameter Range (Metric)
    27.4-45.7 mm
    Cable Shielding
    Concentric Neutral (CN)
    Case Quantity
    1
    Conductor Size by Voltage
    (5 kV, 100%) 750-1000 kcmil, (5 kV, 133%) 750-1500 kcmil, (8 kV, 100%) 750-1500 kcmil, (8 kV, 133%) 500-1250 kcmil, (15 kV) 500-1250 kcmil, (25/28 kV) 350-750 kcmil
    Conductor Sizes
    1000 kcmil, 1250 kcmil, 1500 kcmil, 250 kcmil, 300 kcmil, 350 kcmil, 4/0 AWG, 400 kcmil, 500 kcmil, 600 kcmil, 750 kcmil
    Family
    QT-II
    Indoor/Outdoor
    Outdoor Skirted
    Insulation Level
    100%, 133%
    Insulation Outer Diameter (Imperial)
    1.08 in, 1.09 in, 1.1 in, 1.11 in, 1.12 in, 1.13 in, 1.14 in, 1.15 in, 1.16 in, 1.17 in, 1.18 in, 1.19 in, 1.2 in, 1.21 in, 1.22 in, 1.23 in, 1.24 in, 1.25 in, 1.26 in, 1.27 in, 1.28 in, 1.29 in, 1.3 in, 1.31 in, 1.32 in, 1.33 in, 1.34 in, 1.35 in, 1.36 in, 1.37 in, 1.38 in, 1.39 in, 1.4 in, 1.41 in, 1.42 in, 1.43 in, 1.44 in, 1.45 in, 1.46 in, 1.47 in, 1.48 in, 1.49 in, 1.5 in, 1.51 in, 1.52 in, 1.53 in, 1.54 in, 1.55 in, 1.56 in, 1.57 in, 1.58 in, 1.59 in, 1.6 in, 1.61 in, 1.62 in, 1.63 in, 1.64 in, 1.65 in, 1.66 in, 1.67 in, 1.68 in, 1.69 in, 1.7 in, 1.71 in, 1.72 in, 1.73 in, 1.74 in, 1.75 in, 1.76 in, 1.77 in, 1.78 in, 1.79 in, 1.8 in
    Insulation Outer Diameter (Metric)
    27.432 mm, 27.686 mm, 27.94 mm, 28.194 mm, 28.448 mm, 28.702 mm, 28.956 mm, 29.21 mm, 29.464 mm, 29.718 mm, 29.972 mm, 30.226 mm, 30.48 mm, 30.734 mm, 30.988 mm, 31.242 mm, 31.496 mm, 31.75 mm, 32.004 mm, 32.258 mm, 32.512 mm, 32.766 mm, 33.02 mm, 33.274 mm, 33.528 mm, 33.782 mm, 34.036 mm, 34.29 mm, 34.544 mm, 34.798 mm, 35.052 mm, 35.306 mm, 35.56 mm, 35.814 mm, 36.068 mm, 36.322 mm, 36.576 mm, 36.83 mm, 37.084 mm, 37.338 mm, 37.592 mm, 37.846 mm, 38.1 mm, 38.354 mm, 38.608 mm, 38.862 mm, 39.116 mm, 39.37 mm, 39.624 mm, 39.878 mm, 40.132 mm, 40.386 mm, 40.64 mm, 40.894 mm, 41.148 mm, 41.402 mm, 41.656 mm, 41.91 mm, 42.164 mm, 42.418 mm, 42.672 mm, 42.926 mm, 43.18 mm, 43.434 mm, 43.688 mm, 43.942 mm, 44.196 mm, 44.45 mm, 44.704 mm, 44.958 mm, 45.212 mm, 45.466 mm, 45.72 mm
    Insulation Rejacketing
    No
    Lug/Stem Connector Included in Kit
    No
    Maximum Installed Length
    18.00 in
    Maximum Installed Length (Metric)
    45.72 cm
    Number of Conductors
    1
    Number of Skirts
    8
    Product Series
    5600
    Product Technology
    Cold Shrink
    RoHS 2011/65/EU Compliant
    Undetermined
    RoHS EU Comments
    Contact 3M for information
    *Important RoHS information
    Voltage
    15 kV, 25/28 kV, 35 kV, 5 kV, 8 kV
    Details
    • One-piece cold shrink termination.
    • High dielectric-constant material regulates the distribution of electric field stress
    • Suitable for outdoor, weather exposed applications
    • Silicone rubber insulation is track-resistance and hydrophobic
    • Silicone cold shrink application provides constant radial pressure, "living seal"
    • Withstands voltages of 5 to 15kV and is 110 kV BIL-rated
    • Meets IEEE Standard 48, Class 1 for outdoor, weather-exposed applications

    3M™ Cold Shrink QT II 5600 & 5680 Series Termination Kit includes a 4 skirt, 1 piece termination. It ensures a pliable, tight seal for concentric neutral cables. The conjunction of high dielectric constant material and silicone rubber insulation allows the termination to withstand voltages of 5 to 15kV.

    Legal Disclaimer

    Manufacturing Origin: USA

    The designation that a product is Manufactured in the USA means the product undergoes substantial transformation in one of our U.S. Manufacturing plants. Some products contain imported components.

    Note: 3M products offered on a government contract that require country of origin representation must be certified by 3M Trade Compliance. Contact customer service at 800-245-3573 to request a certificate.
    Follow Us
    The brands listed above are trademarks of 3M.
    Change Location
    United States - English