1. All 3M Products
  • 3M™ Cold Shrink QT-II Outdoor Termination Kit 5604, CN Shielding, 5-35 kV, 0.637-1.12 in (16-28 mm) Cable Insul. O.D., 1/kit
  • 3M™ Cold Shrink QT-II Outdoor Termination Kit 5604, CN Shielding, 5-35 kV, 0.637-1.12 in (16-28 mm) Cable Insul. O.D., 1/kit

    Part Number 56043M ID 80610154785UPC 00054007080022
    • One-piece cold shrink termination.
    • High dielectric-constant material regulates the distribution of electric field stress
    • Suitable for outdoor, weather exposed applications
    • Silicone rubber insulation is track-resistance and hydrophobic
     More...
    Specifications
    Attribute Name
    Value
    Agency Approvals
    IEEE
    BIL
    200 kV
    Brand
    3M™
    Breakout Boot
    No
    Cable Insulation Outside Diameter Range
    0.64-1.12 in
    Cable Insulation Outside Diameter Range (Metric)
    16.3-28.4 mm
    Cable Shielding
    Concentric Neutral (CN)
    Conductor Size by Voltage
    (5 kV, 100%) 3/0 AWG-500 kcmil, (5 kV, 133%) 2/0 AWG-500 kcmil, (8 kV, 100%) 2/0 AWG-500 kcmil, (8 kV, 133%):1/0 AWG-350 kcmil, (15 kV) 4-4/0 AWG, (25/28 kV) 4-2/0 AWG, (35 kV) 2-1/0 AWG
    Conductor Sizes
    1 AWG, 1/0 AWG, 2 AWG, 2/0 AWG, 250 kcmil, 3/0 AWG, 300 kcmil, 350 kcmil, 4 AWG, 4/0 AWG, 400 kcmil, 500 kcmil
    Family
    QT-II
    Indoor/Outdoor
    Outdoor Skirted
    Insulation Level
    100%, 133%
    Insulation Outer Diameter (Imperial)
    0.64 in, 0.65 in, 0.66 in, 0.67 in, 0.68 in, 0.69 in, 0.7 in, 0.71 in, 0.72 in, 0.73 in, 0.74 in, 0.75 in, 0.76 in, 0.77 in, 0.78 in, 0.79 in, 0.8 in, 0.81 in, 0.82 in, 0.83 in, 0.84 in, 0.85 in, 0.86 in, 0.87 in, 0.88 in, 0.89 in, 0.9 in, 0.91 in, 0.92 in, 0.93 in, 0.94 in, 0.95 in, 0.96 in, 0.97 in, 0.98 in, 0.99 in, 1 in, 1.01 in, 1.02 in, 1.03 in, 1.04 in, 1.05 in, 1.06 in, 1.07 in, 1.08 in, 1.09 in, 1.1 in, 1.11 in, 1.12 in
    Insulation Outer Diameter (Metric)
    16.256 mm, 16.51 mm, 16.764 mm, 17.018 mm, 17.272 mm, 17.526 mm, 17.78 mm, 18.034 mm, 18.288 mm, 18.542 mm, 18.796 mm, 19.05 mm, 19.304 mm, 19.558 mm, 19.812 mm, 20.066 mm, 20.32 mm, 20.574 mm, 20.828 mm, 21.082 mm, 21.336 mm, 21.59 mm, 21.844 mm, 22.098 mm, 22.352 mm, 22.606 mm, 22.86 mm, 23.114 mm, 23.368 mm, 23.622 mm, 23.876 mm, 24.13 mm, 24.384 mm, 24.638 mm, 24.892 mm, 25.146 mm, 25.4 mm, 25.654 mm, 25.908 mm, 26.162 mm, 26.416 mm, 26.67 mm, 26.924 mm, 27.178 mm, 27.432 mm, 27.686 mm, 27.94 mm, 28.194 mm, 28.448 mm
    Insulation Rejacketing
    No
    Lug/Stem Connector Included in Kit
    No
    Maximum Installed Length
    16.00 in
    Maximum Installed Length (Metric)
    40.64 cm
    Number of Conductors
    1
    Number of Skirts
    8
    Voltage
    15 kV, 25 kV, 35 kV, 5 kV, 8 kV
    Details
    • One-piece cold shrink termination.
    • High dielectric-constant material regulates the distribution of electric field stress
    • Suitable for outdoor, weather exposed applications
    • Silicone rubber insulation is track-resistance and hydrophobic
    • Silicone cold shrink application provides constant radial pressure, "living seal"
    • Withstands voltages of 5 to 15kV and is 110 kV BIL-rated
    • Meets IEEE Standard 48, Class 1 for outdoor, weather-exposed applications

    3M™ Cold Shrink QT II 5600 & 5680 Series Termination Kit includes a 4 skirt, 1 piece termination. It ensures a pliable, tight seal for concentric neutral cables. The conjunction of high dielectric constant material and silicone rubber insulation allows the termination to withstand voltages of 5 to 15kV.

    Follow Us
    The brands listed above are trademarks of 3M.
    Change Location