  • 3M™ Attest™ Rapid Readout Biological Indicators for steam, 1292
  • 3M™ Attest™ Rapid Readout Biological Indicators for steam, 1292

    Catalog Number 12923M ID 70200620527
    • Provides results in three hours
    • Self-contained biological indicators significantly reduce possibility of contamination, minimizing false positives and assuring more accurate results
    • Faster result time, making it possible to quarantine every load and eliminate recalls
    • System can help reduce the costs associated with fighting infections
     More...
    Specifications
    Biological Indicator System
    Rapid
    Brand
    Attest™
    Cap Color
    Brown
    Model
    1292
    Product Type
    Biological Indicator
    Product Use
    Load Monitoring
    Sterilization Method
    Steam
    Product Details
    • Provides results in three hours
    • Self-contained biological indicators significantly reduce possibility of contamination, minimizing false positives and assuring more accurate results
    • Faster result time, making it possible to quarantine every load and eliminate recalls
    • System can help reduce the costs associated with fighting infections
    • Color-coded for quick reference and easy use
    • Protective packaging

    Three-hour readout, brown cap, Rapid Readout Biological Indicator for Steam 250°F/121°C gravity or 270°F/132°C vacuum assisted sterilization cycles

    Biological indicators provide the best assurance of sterility by challenging the sterilizer with quantifiable, highly resistant Bacillus stearothermophilus spores. The system includes rapid readout biological indicators, disposable test packs, auto-readers and log books. Biological indicators are used for load control monitoring which is the process by which a load is monitored and released based on the result of a biological indicator (BI) in a test pack.3M™ Attest™ 1292 Rapid Readout Biological Indicators for 121° C (250° F) vacuum-assisted cyclesSelf-contained (BI) for 121° C (250° F) gravity/132° C (270° F) vacuum-assisted cycles consisting of a Bacillus stearothermophilus spore strip; sealed glass ampule with growth medium and dual indicator system; brown color-coded cap with holes for sterilant penetration and a hydrophobic filter as a bacterial barrier; and a chemical indicator on the label that changes from rose to brown when processed. After sterilization, the vial is "crushed" to join the growth media with the processed spore strip. The (BI) is incubated for three hours in the Attest 190 series auto-reader for a fluorescent reading. A red light indicates a positive result.3M™ Attest™ 190 Series Auto-readerDual function fluorescent reader/incubator for use with Attest rapid readout steam biological indicators. The incubator runs at 60° C (140° F). The (BI) is crushed in the crusher well, transferred to the incubation wells for 3 hours, then placed in the reader well until a red or green light goes on. The auto-reader must be calibrated with a processed, non-incubated test vial every 12 hours or anytime the calibration light comes on. The auto-reader UV lamp and starter must be changed every 6 months for the test results to be valid. In addition, a positive control (unprocessed BI) from the same lot and manufacturing date must be incubated daily and each time the auto-reader is calibrated.

    Suggested Applications

    • Designed to monitor 250(deg)F/121(deg)C gravity and 270(deg)F/132(deg)C vacuum-assisted steam sterilization processes