Warning signs of NO2**:
- a bleach like odour and/ or a yellowish- brown haze at the silage surface or near the feed room floor
- unnatural breathing or coughing by livestock and people may indicate the presence of NO2
- dead flies, cats or rodents on the feed room floor or dead birds inside the silo, point to build up of silo gas
Warning signs of CO2**:
- this potential killer is colourless, tasteless and odourless
- unnatural breathing or coughing by livestock and people may indicate the presence of CO2
**If any of these conditions exist, immediately clear the area of people and livestock.
|
 |
 |
 |
|